====== MNET Series ====== MNET Series is a family of communication slave products whose digital I/O, analog I/O, temperature sensor inputs, and high-speed pulse I/O can be controlled from a master device such as a PC, HMI, or PLC using Modbus or LS Industrial Systems Cnet. The CPU module includes DIP switches for setting the baud rate and slave address. Supports 1 RS-232 channel, 1 RS-485 channel, and 1 UART channel. This product does not accept downloaded user programs. Select Modbus RTU Slave or LS Industrial Systems Cnet Slave when ordering. ===== How to read model names ===== * The leading number in ''8A'', ''16A'', ''32A'', etc. is the **number of digital inputs**. * The number before ''R'' is the **number of relay outputs**. * The number before ''T'' is the **number of transistor outputs**. * ''8A8R'' is a model with 8 digital inputs and 8 relay outputs. * ''8A8T'' is a model with 8 digital inputs and 8 transistor outputs. ===== MNET Series comparison ===== ^ Model ^ Communication \\ Protocol ^ Digital inputs ^ Relay outputs ^ Transistor outputs ^ RS-232 ^ RS-485 ^ UART ^ | [[:en-us_products:mnet_8a8r|MNET-8A8R]] | Modbus RTU \\ LS Industrial Systems Cnet | 8 | 8 | 0 | 1 | 1 | 1 | | [[:en-us_products:mnet_8a8t|MNET-8A8T]] | Modbus RTU \\ LS Industrial Systems Cnet | 8 | 0 | 8 | 1 | 1 | 1 | | [[:en-us_products:mnet_16a16r|MNET-16A16R]] | Modbus RTU \\ LS Industrial Systems Cnet | 16 | 16 | 0 | 1 | 1 | 1 | | [[:en-us_products:mnet_32a32r|MNET-32A32R]] | Modbus RTU \\ LS Industrial Systems Cnet | 32 | 32 | 0 | 1 | 1 | 1 | Optional modules provide analog I/O, temperature sensor inputs, and high-speed pulse I/O. ===== MNET Series specifications ===== Use the addresses for the communication protocol selected when ordering. The table shows each model's base digital input and output addresses. ^ Product ^ Address type ^ Modbus RTU addresses ^ LS Cnet addresses ^ | [[en-us_products:mnet_8a8r|MNET-8A8R]] | Digital inputs | 0–7 | P0000–P0007 | | ::: | Relay outputs | 32–39 | P0032–P0039 | | [[en-us_products:mnet_8a8t|MNET-8A8T]] | Digital inputs | 0–7 | P0000–P0007 | | ::: | Transistor outputs | 32–39 | P0032–P0039 | | [[en-us_products:mnet_16a16r|MNET-16A16R]] | Digital inputs | 0–15 | P0000–P0015 | | ::: | Relay outputs | 32–47 | P0032–P0047 | | [[en-us_products:mnet_32a32r|MNET-32A32R]] | Digital inputs | 0–31 | P0000–P0031 | | ::: | Relay outputs | 32–63 | P0032–P0063 | ===== Optional modules ===== The following optional modules can be added to the product configuration. The product is assembled and shipped in the selected configuration. \\ Users cannot add or remove I/O modules or optional modules. ^ Code ^ Function ^ Points per module ^ Maximum configuration ^ | X | Analog inputs | 4 points | Up to 5 units, 20 points | | F | PT100Ω temperature sensor input | 4 points | Up to 5 units, 20 points | | Y | Analog outputs | 3 points | Up to 4 units, 12 points | | K | High-speed pulse outputs | 6 points | Up to 2 units, 12 points | The combined total of analog inputs and PT100Ω temperature sensor inputs cannot exceed 20 points. \\ The combined total of analog outputs and high-speed pulse outputs cannot exceed 12 points. \\ Products with optional modules are custom-built, so exchanges or refunds may be difficult. ===== Communication settings ===== ^ Item ^ Selection range ^ Setting method ^ | Communication protocol | Modbus RTU Slave \\ LS Industrial Systems Cnet Slave | Select when ordering | | Baud rate | 9,600 / 14,400 / 19,200 / 28,800 / 38,400 / 57,600 / 76,800 / 115,200bps | 3-bit DIP switch | | Slave address | 0~15 | 4-bit DIP switch | | Communication terminals | RS-232 \\ RS-485 \\ UART | Use the port wired to the master device | [[:en-us_products:overview|← Back to product selection guide]]