MP STUDIO 2 Phase 6 · Check, Communication and Download

한국어 | English

The ladder you write is converted into device code and downloaded to the device. This page describes the program check to look at before downloading, the communication port settings, downloading and checking the firmware, and checking the mnemonics and program memory.

Figure 1. How the ladder is downloaded to the device

Program Check

MP STUDIO 2 checks the whole program every time you edit it. The results appear on the canvas right away, without a separate compile step.

Figure 2. An error cell and a warning cell

Shortcut Menu Action
Ctrl+. / Ctrl+, Search → Next Error / Previous Error Moves between error cells.
Alt+. / Alt+, Search → Next Warning / Previous Warning Moves between warning cells.

While there are error cells, you can neither download nor monitor. Correct all error cells before downloading.

Communication Port

Select Setting → Communication Port or click the Communication button in the top band to open the Communication Setting window. The upper part is the link used for downloading, and the lower part is the communication settings of the device's serial channels.

Figure 3. The Communication Setting window

Download Channel

Figure 4. ETHERNET selected with an IP address and port number entered

Ethernet download is available when the device supports an Ethernet connection. Check the product page to see whether your device supports it.

Serial Channels

Choose a channel in the ③ Serial 1, Serial 2 and Serial 3 tabs, then set ④ the communication parameters and ⑤ the Mode. The number of channels depends on the model. MPS-8A4R(T)-S, MPS-8A8R(T)-S, MPS-16A8R(T)-R2 and MPS-16A16R(T) have only Serial 1.

Item Choices
Mode Normal · Modbus RTU Slave · Cubloc Modbus RTU Slave · CNET (XBC/LINK) · IBUS Master · IBUS Slave · Modbus RTU Master
Baud Rate 2400 · 4800 · 9600 · 14400 · 19200 · 28800 · 38400 · 57600 · 76800 · 115200
Data Bits, Parity, Stop Bits Set them to match the device you connect to.
Slave ID The station number of this device in a slave mode.
⑥ Use this channel for download When on, programs can be downloaded through this channel. The baud rate must then be 115200.

The baud rate, data bits, parity and stop bits must match the device at the other end. A Modbus RTU Master channel cannot be used for downloading, so turn off Use this channel for download for it. The Modbus master list is described in Phase 9 · Modbus RTU Master.

Ethernet Connection

When the download channel is ETHERNET, a Connect button appears in the top band.

  1. Click Connect or select Run → Connect.
  2. When the device pill shows Ethernet connected · IP:port, the connection is made. The button changes to Disconnect.
  3. To disconnect, click Disconnect.

Figure 5. The device pill connected over Ethernet and the Disconnect button

Serial (COM) channels do not need a separate connection. The port is opened for each download or monitoring command.

Download

  1. Make sure there are no error cells.
  2. Click Download in the top band or select Run → Download (Ctrl+T).
  3. Watch the progress in the progress window. Do not turn off the device or disconnect the cable during the transfer.
  4. When the Download complete window appears, click OK, or click Monitoring to start monitoring right away.

Figure 6. The download progress window and completion window

Caution: Ctrl+T and Download in the cell menu download immediately, without a confirmation window. If the device is connected to running equipment, its outputs may change, so put the equipment in a safe state before you continue.

Firmware Version and Firmware Download

Select Run → Firmware Version to read the firmware version of the connected device. A notice such as The firmware version is 0.2.6. appears at the bottom right of the screen. While monitoring, the status pills also show the firmware version (FW).

Figure 7. The firmware version notice

Run → Firmware Download updates the firmware of the device. Use it when a window asking you to update the firmware appears during a download. Do not turn off the device or disconnect the cable while the firmware is being updated.

Mnemonic Conversion

Select Run → Mnemonic or click the Mnemonic button in the top band to open the Mnemonic Viewer window, which shows the ladder converted into a list of instructions (mnemonics).

Figure 8. The Mnemonic Viewer window and the linked ladder cell

Program Memory

Select Run → Program Memory to convert the current program into device code and show how much of the device's program memory is left. If the program exceeds the capacity, the number of excess bytes is shown, and you cannot download in that state.

Figure 9. The Program Memory window

Clear EEPROM

Run → Clear EEPROM erases all retentive (EEPROM) values in the device. Erased values cannot be restored, so a confirmation window is shown before it runs. This command is available only on a serial (COM) download channel.