MPA Series is an assembled industrial PLC combining a CPU module with digital input and output modules.
Analog input/output, temperature sensor input, and high-speed pulse output modules can be added as options.
The selected I/O and optional modules are assembled and shipped as one product. Users cannot add or remove modules.
MPA-48A48T provides 48 digital inputs and 48 SINK transistor outputs.
Program with ladder logic using MP STUDIO.
| Category | Quantity | Terminal / Item | Specifications |
|---|---|---|---|
| Programming method | - | - | MP STUDIO MP STUDIO2 (Ladder logic program) |
| Power | - | Supply voltage | DC 12~24V For DC 24V, a power supply rated 0.5A or more is recommended |
| Digital inputs | 48 points (Isolated) | Module 0: P0~P7 Module 1: P8~P15 Module 2: P16~P23 Module 3: P24~P31 Module 4: P32~P39 Module 5: P40~P47 | Operating input voltage DC 0~80V HIGH detection: DC 5V or higher Optocoupler isolation |
| Transistor outputs | 48 points (Isolated SINK) | Module 0: P64~P71 Module 1: P72~P79 Module 2: P80~P87 Module 3: P88~P95 Module 4: P96~P103 Module 5: P104~P111 | P24: DC 5~24V Load voltage DC 0~100V Max. 1A/1 points, 8A/1COM |
| Optional modules | up to 20 points | Analog inputs PT100Ω temperature sensor input | Optional specifications |
| up to 12 points | Analog outputs High-speed pulse outputs | Optional specifications | |
| Communication Channels | 1 channel each | RS-232 RS-485 UART I²C | Built into the CPU module |
| Memory | - | Flash Data | 256KB 8KB |
See the one-channel digital-input check before wiring for the first time. →
The diagram shows a wiring example for module 0. For other modules, use the corresponding contact numbers in the table. This example uses a DC 24V supply; each group can use PNP or NPN depending on its COM wiring.
The digital inputs are isolated by optocouplers. NPN or PNP switches and sensors can be used depending on the COM terminal wiring of each input module.
See the one-channel SINK transistor-output check before wiring for the first time. →
The diagram shows a wiring example for module 0. For other modules, use the corresponding contact numbers in the table.
Connect DC 5~24V to P24 on each module and connect the supply GND to N24. When the output is ON, the output contact is connected to the GND supplied at N24.
| Module | Maximum points | Function |
|---|---|---|
| Analog inputs | 20 points | DC 0~5V, DC 0~10V, 0~20mA or NTC temperature sensor input |
| PT100Ω temperature sensor input | 20 points | 2-wire or 3-wire PT100Ω temperature sensor input |
| Analog outputs | 12 points | DC 0~5V, DC 0~10V or 0~20mA output |
| High-speed pulse outputs | 12 points | Pulse output up to 1MHz |
The I²C diagram shows a connection example for a 5V device. Check the other device's signal voltage before connecting UART.
Control the CPU module STATUS LED with the @SLED contact in MP STUDIO.
MPA tab and select MPA-48A48R(T).| Item | Dimensions |
|---|---|
| Product width | 190mm |
| Body height | 108mm |
| Overall height | Clip open: 120.42mm Clip closed: 115.16mm |
| Product depth | Body: 79mm Maximum with terminals: 83mm |
| Mounting hole spacing | 162mm |
| Mounting hole diameter | Ø4mm |
| DIN rail | 35mm |