 MNET-32A32R is a communication slave I/O device that allows a master device such as a PC, HMI, or PLC to read digital inputs and control relay outputs over a communication link. MNET-32A32R is a communication slave I/O device that allows a master device such as a PC, HMI, or PLC to read digital inputs and control relay outputs over a communication link.
  
-Provides 32 digital inputs and 32 relay outputs as standard. Select Modbus RTU Slave or LS Industrial Systems Cnet Slave when ordering.+The device provides 32 digital inputs and 32 relay outputs as standard. Select Modbus RTU Slave or LS Industrial Systems Cnet Slave when ordering.
  
 This product does not accept downloaded user programs. The master device controls I/O by reading or writing addresses on MNET-32A32R. This product does not accept downloaded user programs. The master device controls I/O by reading or writing addresses on MNET-32A32R.
Line 32: Line 32:
 ===== Digital inputs ===== ===== Digital inputs =====
  
 +[[:en-us_guide:wiring#digital_input_one_channel_check|See the one-channel digital-input check before wiring for the first time. →]]
 ^ Group ^ Number of inputs ^ Communication address ^ Input configuration ^ ^ Group ^ Number of inputs ^ Communication address ^ Input configuration ^
 | Input 0~7 group | 0~7 | Modbus 0~7 \\ Cnet P0000~P0007 | 8 isolated digital inputs \\ DC 5~24V \\ NPN/PNP inputs | | Input 0~7 group | 0~7 | Modbus 0~7 \\ Cnet P0000~P0007 | 8 isolated digital inputs \\ DC 5~24V \\ NPN/PNP inputs |
Line 42: Line 43:
 ===== Relay outputs ===== ===== Relay outputs =====
  
 +[[:en-us_guide:wiring#relay_output_one_channel_check|See the one-channel relay-output check before wiring for the first time. →]]
 ^ Group ^ Number of outputs ^ Communication address ^ Output configuration ^ ^ Group ^ Number of outputs ^ Communication address ^ Output configuration ^
 | Output 0~3 group | 0~3 | Modbus 32~35 \\ Cnet P0032~P0035 | 4 dry relay contacts | | Output 0~3 group | 0~3 | Modbus 32~35 \\ Cnet P0032~P0035 | 4 dry relay contacts |
Line 93: Line 95:
  
 ^ Code ^ Function ^ Points per module ^ Maximum configuration ^ Value format ^ ^ Code ^ Function ^ Points per module ^ Maximum configuration ^ Value format ^
-| X | Analog inputs | 4 points | X~X5, up to 20 points | 15bit, 0~32,767 \\ NTC mode: temperature ×10 |+| X | Analog inputs | 4 points | X~X5, up to 20 points | 15-bit, 0~32,767 \\ NTC mode: temperature ×10 |
 | F | PT100Ω temperature sensor input | 4 points | F~F5, up to 20 points | −200~800℃ \\ Temperature ×10 | | F | PT100Ω temperature sensor input | 4 points | F~F5, up to 20 points | −200~800℃ \\ Temperature ×10 |
-| Y | Analog outputs | 3 points | Y~Y4, up to 12 points | 16bit, 0~65,535 |+| Y | Analog outputs | 3 points | Y~Y4, up to 12 points | 16-bit, 0~65,535 |
 | K | High-speed pulse outputs | 6 points | K~K2, up to 12 points | DC 5V, 30mA or less \\ Max. 1MHz | | K | High-speed pulse outputs | 6 points | K~K2, up to 12 points | DC 5V, 30mA or less \\ Max. 1MHz |
  
Line 104: Line 106:
 Configure analog inputs (X) and PT100Ω inputs (F) for **a combined maximum of 20 points**, and analog outputs (Y) and high-speed pulse outputs (K) for **a combined maximum of 12 points**. You cannot order a configuration that simply adds the maximum point count of every module. Configure analog inputs (X) and PT100Ω inputs (F) for **a combined maximum of 20 points**, and analog outputs (Y) and high-speed pulse outputs (K) for **a combined maximum of 12 points**. You cannot order a configuration that simply adds the maximum point count of every module.
  
-Options are assembled and shipped in the selected configuration; users cannot add or remove I/O or optional modules. Also see [[:en-us_products:mnet#옵션_모듈|MNET Series option configuration guide]].+Options are assembled and shipped in the selected configuration; users cannot add or remove I/O or optional modules. Also see [[:en-us_products:mnet#optional_modules|MNET Series option configuration guide]].
  
 ==== Interpreting option values ==== ==== Interpreting option values ====
Line 153: Line 155:
   - Verify that the load is safe for an output test, then control the first output. The Modbus RTU internal address is ''32'' and the LS Industrial Systems Cnet address is ''P0032''.   - Verify that the load is safe for an output test, then control the first output. The Modbus RTU internal address is ''32'' and the LS Industrial Systems Cnet address is ''P0032''.
   - After verification, apply all required addresses in order.   - After verification, apply all required addresses in order.
 +