| ====== MP STUDIO 2 Phase 10 · Troubleshooting ====== | ====== MP STUDIO 2 Phase 10 · Troubleshooting ====== | ||
| - | |||
| - | [[products: | ||
| When downloading, | When downloading, | ||
| Line 9: | Line 7: | ||
| ^ Symptom ^ What to check ^ | ^ Symptom ^ What to check ^ | ||
| | The download does not start. | You cannot download while there are red error cells. Go through the error cells with '' | | The download does not start. | You cannot download while there are red error cells. Go through the error cells with '' | ||
| - | | **Choosing ETHERNET as the download port requires an IP address and a port number.** | Enter the IP address and port number in **Setting | + | | **Choosing ETHERNET as the download port requires an IP address and a port number.** | Enter the IP address and port number in **Settings |
| - | | The download ends with **Communication error. Check the port and the device** | Check that the COM number of the download channel matches the number in Device Manager, and check the cable and the device | + | | The download ends with **Communication error. Check the port and the PLC.** | Check that the COM number of the download channel matches the number in Device Manager, and check the cable and the PLC power. If the PLC still does not respond when you download again, turn the PLC off and on and try again. | |
| - | | **Checksum (01) is wrong. | + | | **Checksum (01) is wrong. |
| - | | **The device | + | | **The PLC was still waiting in download mode after an earlier download was interrupted.** | An earlier download was interrupted. Download again. | |
| - | | A message says the channel is Modbus RTU Master and cannot be used for download. | In the **Communication | + | | A message says the channel is Modbus RTU Master and cannot be used for download. | In the **Communication |
| | A message says the program exceeds the program memory. | Check how much is exceeded with **Run → Program Memory** and make the program smaller. | | | A message says the program exceeds the program memory. | Check how much is exceeded with **Run → Program Memory** and make the program smaller. | | ||
| - | | A window asks you to update the firmware. | The firmware version of the device | + | | A window asks you to update the firmware. | The firmware version of the PLC differs from the version MP STUDIO 2 requires. Follow the instructions to update the firmware. | |
| ===== Monitoring ===== | ===== Monitoring ===== | ||
| ^ Symptom ^ What to check ^ | ^ Symptom ^ What to check ^ | ||
| - | | The device pill shows **No response**. | Check the cable, the device | + | | The PLC status indicator |
| - | | The device pill shows **Device | + | | The PLC status indicator |
| - | | Values appear in the wrong cells. | A different project may be on the device. Download the current project again. | | + | | Values appear in the wrong cells. | A different project may be on the PLC. Download the current project again. | |
| | **Monitoring (fixed areas only)** is shown. | The program check failed, so only the fixed memory areas are being read. Once you correct the error cells, all values are read. | | | **Monitoring (fixed areas only)** is shown. | The program check failed, so only the fixed memory areas are being read. Once you correct the error cells, all values are read. | | ||
| - | | Outputs behave differently from the ladder. | Check whether the device pill shows **Forced N**. Forced values remain even after a power cycle. Release them in the **FORCE INPUT / OUTPUT** window with **Clear → Apply Force**. | | + | | Outputs behave differently from the ladder. | Check whether the PLC status indicator |
| ===== Editing and Program Check ===== | ===== Editing and Program Check ===== | ||
| ^ Symptom ^ What to check ^ | ^ Symptom ^ What to check ^ | ||
| - | | An I/O address cell is red. | The address does not exist on the selected model. The Inspector shows the range that can be used on that model. Check that the model in the device pill matches your actual | + | | An I/O address cell is red. | The address does not exist on the selected model. The Inspector shows the range that can be used on that model. Check that the model in the PLC status indicator |
| - | | A cell with an address such as '' | + | | A cell with an address such as '' |
| | A symbol cannot be placed. | You cannot place a symbol on a function block. Select an empty cell. | | | A symbol cannot be placed. | You cannot place a symbol on a function block. Select an empty cell. | | ||
| | Two coil cells with the same address are red. | Each bit should be turned on and off by one coil only. If there are several conditions, combine them in parallel (OR) in one rung, or use SET and RESET. | | | Two coil cells with the same address are red. | Each bit should be turned on and off by one coil only. If there are several conditions, combine them in parallel (OR) in one rung, or use SET and RESET. | | ||
| - | | An edge cell is red. | An address that the device | + | | An edge cell is red. | An address that the PLC overwrites, such as an input ('' |
| | Monitoring turned off after an edit made during monitoring. | Monitoring turns off when the program changes (**Monitoring stopped because the program changed.**). Download again and then turn monitoring on. | | | Monitoring turned off after an edit made during monitoring. | Monitoring turns off when the program changes (**Monitoring stopped because the program changed.**). Download again and then turn monitoring on. | | ||
| - | | Some cells are hatched in simulation. | The simulator cannot run those cells. Check their behavior on the real device. | | + | | Some cells are hatched in simulation. | The simulator cannot run those cells. Check their behavior on the real PLC. | |
| ===== Getting Support ===== | ===== Getting Support ===== | ||