User Tools

Site Tools


en-us_products:mpa_8a8r

Differences

This shows you the differences between two versions of the page.

Link to this comparison view

Next revision
Previous revision
en-us_products:mpa_8a8r [2026/09/07 21:52] – 만듦 - 바깥 편집 127.0.0.1en-us_products:mpa_8a8r [2026/10/25 08:42] (current) – external edit 127.0.0.1
Line 1: Line 1:
 ====== MPA-8A8R ====== ====== MPA-8A8R ======
  
-MPA Series is an assembled industrial PLC combining a CPU module with digital input and output modules. \\+The MPA Series comprises modular industrial PLCs assembled from a CPU module and digital input and output modules. \\
 Analog input/output, temperature sensor input, and high-speed pulse output modules can be added as options. \\ Analog input/output, temperature sensor input, and high-speed pulse output modules can be added as options. \\
 The selected I/O and optional modules are assembled and shipped as one product. Users cannot add or remove modules. The selected I/O and optional modules are assembled and shipped as one product. Users cannot add or remove modules.
Line 23: Line 23:
 |  Power  |  -  |  Supply voltage  | DC 12~24V \\ For DC 24V, a power supply rated 0.5A or more is recommended  | |  Power  |  -  |  Supply voltage  | DC 12~24V \\ For DC 24V, a power supply rated 0.5A or more is recommended  |
 |  Digital inputs  |  8 points \\ (Isolated)  |  Module 0: P0~P7  | Operating input voltage DC 0~80V \\ HIGH detection: DC 5V or higher \\ Optocoupler isolation  | |  Digital inputs  |  8 points \\ (Isolated)  |  Module 0: P0~P7  | Operating input voltage DC 0~80V \\ HIGH detection: DC 5V or higher \\ Optocoupler isolation  |
-|  Relay outputs  |  8 points \\ (Isolated dry contacts)  |  Module 0: P32~P39  | DC 0~30V or AC 0~250V \\ Max. 5A/1 points, 8A/1COM  |+|  Relay outputs  |  8 points \\ (Isolated dry contacts)  |  Module 0: P32~P39  | DC 0~30V or AC 0~250V \\ Max. 5A/1 point, 8A/1COM  |
 |  High-speed counter inputs  |  2 points \\ (Isolated)  |  P0, P1  | Max. 8kHz \\ Shared with digital inputs  | |  High-speed counter inputs  |  2 points \\ (Isolated)  |  P0, P1  | Max. 8kHz \\ Shared with digital inputs  |
 |  Encoder Inputs  |  2 points \\ (Isolated)  |  P0(A)·P2(B) \\ P1(A)·P3(B)  | Max. 8kHz \\ Shared with high-speed counter inputs  | |  Encoder Inputs  |  2 points \\ (Isolated)  |  P0(A)·P2(B) \\ P1(A)·P3(B)  | Max. 8kHz \\ Shared with high-speed counter inputs  |
Line 34: Line 34:
 ===== Digital inputs ===== ===== Digital inputs =====
  
 +[[:en-us_guide:wiring#digital_input_one_channel_check|See the one-channel digital-input check before wiring for the first time. →]]
 ^ Module ^ Group ^ Input contacts ^ Input configuration ^ Terminal blocks and wiring examples ^ ^ Module ^ Group ^ Input contacts ^ Input configuration ^ Terminal blocks and wiring examples ^
 | Module 0 | COM0 \\ COM1 | P0~P3 \\ P4~P7 | 8 isolated digital inputs \\ 4 points/1COM \\ P0/P1 share high-speed counter inputs |  {{:en-us_products:mpa-input-8-wiring.svg?740|MPA-8A8R digital input wiring example}}  | | Module 0 | COM0 \\ COM1 | P0~P3 \\ P4~P7 | 8 isolated digital inputs \\ 4 points/1COM \\ P0/P1 share high-speed counter inputs |  {{:en-us_products:mpa-input-8-wiring.svg?740|MPA-8A8R digital input wiring example}}  |
Line 43: Line 44:
 ===== Relay outputs ===== ===== Relay outputs =====
  
 +[[:en-us_guide:wiring#relay_output_one_channel_check|See the one-channel relay-output check before wiring for the first time. →]]
 ^ Module ^ Group ^ Output contacts ^ Contact configuration ^ Terminal blocks and wiring examples ^ ^ Module ^ Group ^ Output contacts ^ Contact configuration ^ Terminal blocks and wiring examples ^
 | Module 0 | COM0 \\ COM1 | P32~P35 \\ P36~P39 | 8 relay outputs \\ 4 points/1COM |  {{:en-us_products:mpa-relay-8-p32-wiring.svg?740|MPA-8A8R relay output wiring example}}  | | Module 0 | COM0 \\ COM1 | P32~P35 \\ P36~P39 | 8 relay outputs \\ 4 points/1COM |  {{:en-us_products:mpa-relay-8-p32-wiring.svg?740|MPA-8A8R relay output wiring example}}  |
Line 65: Line 67:
  
 ^ Module ^ Maximum points ^ Function ^ ^ Module ^ Maximum points ^ Function ^
-| Analog inputs | 20 points | DC 0~5V, DC 0~10V, 0~20mA or NTC temperature sensor input | +| [[en-us_products:mpa_x|Analog inputs]] | 20 points | DC 0~5V, DC 0~10V, 0~20mA or NTC temperature sensor input | 
-| PT100Ω temperature sensor input | 20 points | 2-wire or 3-wire PT100Ω temperature sensor input | +| [[en-us_products:mpa_f|PT100Ω temperature sensor input]] | 20 points | 2-wire or 3-wire PT100Ω temperature sensor input | 
-| Analog outputs | 12 points | DC 0~5V, DC 0~10V or 0~20mA output | +| [[en-us_products:mpa_y|Analog outputs]] | 12 points | DC 0~5V, DC 0~10V or 0~20mA output | 
-| High-speed pulse outputs | 12 points | Pulse output up to 1MHz |+| [[en-us_products:mpa_k|High-speed pulse outputs]] | 12 points | Pulse output up to 1MHz |
  
 ===== Communication and program upload ===== ===== Communication and program upload =====
Line 107: Line 109:
 ^ Rear view ^  ^ ^ Rear view ^  ^
 |  [[https://www.ilogics.net/docs/_media/products:mpa-8a8r-dimension-rear.svg|{{ :en-us_products:mpa-8a8r-dimension-rear.svg?nolink&360 }}]]  |  | |  [[https://www.ilogics.net/docs/_media/products:mpa-8a8r-dimension-rear.svg|{{ :en-us_products:mpa-8a8r-dimension-rear.svg?nolink&360 }}]]  |  |
 +
 +[[https://www.ilogics.net/en-us/products/mpa-8a8r|View MPA-8A8R price and purchase options]]
  
 [[:en-us_products:mpa|← Back to MPA Series comparison]] [[:en-us_products:mpa|← Back to MPA Series comparison]]
  
en-us_products/mpa_8a8r.1788785570.txt.gz · Last modified: by 127.0.0.1

Donate Powered by PHP Valid HTML5 Valid CSS Driven by DokuWiki