en-us_products:mpa_k [2026/09/12 22:11] – 만듦 - 바깥 편집 127.0.0.1en-us_products:mpa_k [2026/09/12 22:18] (current) – external edit 127.0.0.1
Line 1: Line 1:
-====== MPA High-speed Pulse Output K Module ======+====== MPA K Module ======
  
-The K module adds six high-speed pulse outputs to an MPA Series controller. Up to two modules provide 12 channels, with a maximum output frequency of 1 MHz. Y analog outputs and K pulse outputs share a 12-channel maximum.+The K module adds six DC 5 V high-speed pulse outputs to an MPA Series controller. Up to two modules provide 12 channels, with a maximum output frequency of 1 MHz. Y analog outputs and K pulse outputs share a 12-channel maximum.
  
 ===== When to use it ===== ===== When to use it =====
  
 Use the K module with external equipment that accepts pulse inputs, such as a motor controller or dimming device. For analog voltage or current signals, select the [[en-us_products:mpa_y|Y analog output module]]. Use the K module with external equipment that accepts pulse inputs, such as a motor controller or dimming device. For analog voltage or current signals, select the [[en-us_products:mpa_y|Y analog output module]].
 +
 +===== Pulse output example =====
 +
 +In MP STUDIO, the ''FDPWM'' function block uses ''PORT'' for the output port, ''FREQ'' for frequency in Hz, and ''DUTY'' for duty cycle from 0 to 100%. Setting ''PORT=0'', ''FREQ=1000'', and ''DUTY=70'' continuously outputs a 1 kHz pulse at 70% duty cycle on PWM0. Use the ''PWMOFF'' function block to stop the pulse output.
 +
 +PWM0–2 share one pulse generator, as do PWM3–5. If ports in the same group specify different frequencies, the last executed command sets the frequency for that group.
  
 ===== Check before use ===== ===== Check before use =====
Line 12: Line 18:
   * Compare the receiving device's pulse input voltage, permitted frequency, and input circuit with the product specifications.   * Compare the receiving device's pulse input voltage, permitted frequency, and input circuit with the product specifications.
   * If Y modules are also installed, check the combined Y/K channel count.   * If Y modules are also installed, check the combined Y/K channel count.
 +
 +[[https://www.ilogics.net/en-us/resources/downloads/manual/11|View the MPA product manuals]]
  