Line 13: Line 13:
 | Measurement range | −200 to +800°C | | Measurement range | −200 to +800°C |
 | Display resolution | 0.1°C | | Display resolution | 0.1°C |
-| Accuracy stated in the module manual | ±0.1% or less at 25°C ±5°C ambient |+| Accuracy | ±0.1% or less at 25°C ±5°C ambient |
 | Converter | ADS1118 | | Converter | ADS1118 |
 | Maximum configuration | Five F modules; X and F together no more than five modules | | Maximum configuration | Five F modules; X and F together no more than five modules |
Line 61: Line 61:
 </code> </code>
  
-A return value of ''253'' means 25.3°C. The current MPAINO core already contains ''pt100Read()''; the old module manual's ''ILIB.h'' and ''IADC PT(...)'' object are not required.+A return value of ''253'' means 25.3°C. The MPAINO board package includes ''pt100Read()'', so no separate library is needed.
  
 ===== If the value looks wrong ===== ===== If the value looks wrong =====
Line 69: Line 69:
 | Large difference from room temperature | Confirm the PT100 type, two-wire or three-wire diagram, and A/B/B′ terminals for the same channel. | | Large difference from room temperature | Confirm the PT100 type, two-wire or three-wire diagram, and A/B/B′ terminals for the same channel. |
 | Second module reads incorrectly | Distinguish consecutive F-only numbers from the shipped allocation in a mixed X/F configuration. | | Second module reads incorrectly | Distinguish consecutive F-only numbers from the shipped allocation in a mixed X/F configuration. |
-| ''0'' appears | It may be a valid 0.0°C reading. The current core can also return 0 for an absent module, an out-of-range channel, or a failed internal object allocation. Check the hardware and configuration as well. |+| ''0'' appears | It may be a valid 0.0°C reading. An absent module, an out-of-range channel, or a failed internal object allocation may also return 0. Check the hardware and configuration as well. |
  