en-us_products:mpino_8a8r
Differences
This shows you the differences between two versions of the page.
| Both sides previous revisionPrevious revision | |||
| en-us_products:mpino_8a8r [2026/10/07 22:35] – external edit 127.0.0.1 | en-us_products:mpino_8a8r [2026/10/25 08:42] (current) – external edit 127.0.0.1 | ||
|---|---|---|---|
| Line 1: | Line 1: | ||
| ====== MPINO-8A8R ====== | ====== MPINO-8A8R ====== | ||
| - | MPINO-8A8R is a all-in-one industrial Arduino with 8 digital inputs and 8 relay outputs. A single PCB integrates 4 analog inputs, 6 PWM outputs, 2 isolated high-speed counter inputs, 4 interrupt inputs, and RS-232·RS-485·UART·I²C communication. | + | MPINO-8A8R is an all-in-one industrial Arduino with 8 digital inputs and 8 relay outputs. A single PCB integrates 4 analog inputs, 6 PWM outputs, 2 isolated high-speed counter inputs, 4 interrupt inputs, and RS-232·RS-485·UART·I²C communication. |
| Program the controller with Arduino IDE (Arduino C/C++) or MPINO STUDIO 2 (Arduino C/C++ & ladder logic). | Program the controller with Arduino IDE (Arduino C/C++) or MPINO STUDIO 2 (Arduino C/C++ & ladder logic). | ||
| Line 17: | Line 17: | ||
| | Power | - | Supply voltage | | Power | - | Supply voltage | ||
| | Digital inputs | | Digital inputs | ||
| - | | Relay outputs | + | | Relay outputs |
| - | | Analog inputs | + | | Analog inputs |
| | High-speed counter inputs | | High-speed counter inputs | ||
| | Interrupt inputs | | Interrupt inputs | ||
| Line 187: | Line 187: | ||
| [[: | [[: | ||
| ^ Group ^ Terminal ^ Arduino Pin ^ Contact ratings ^ Terminals and Wiring Example ^ | ^ Group ^ Terminal ^ Arduino Pin ^ Contact ratings ^ Terminals and Wiring Example ^ | ||
| - | | COM2 | R(62), R(63) | D62, D63 | AC 250V or DC 30V, Max. 5A/1 points | + | | COM2 | R(62), R(63) | D62, D63 | AC 250V or DC 30V, Max. 5A/1 point | {{: |
| - | | COM3 | R(64), R(65) | D64, D65 | AC 250V or DC 30V, Max. 5A/1 points | + | | COM3 | R(64), R(65) | D64, D65 | AC 250V or DC 30V, Max. 5A/1 point | ::: | |
| - | | COM4 | R(66), R(67) | D66, D67 | AC 250V or DC 30V, Max. 5A/1 points | + | | COM4 | R(66), R(67) | D66, D67 | AC 250V or DC 30V, Max. 5A/1 point | ::: | |
| - | | COM5 | R(68), R(69) | D68, D69 | AC 250V or DC 30V, Max. 5A/1 points | + | | COM5 | R(68), R(69) | D68, D69 | AC 250V or DC 30V, Max. 5A/1 point | ::: | |
| Relay outputs are dry contacts that physically connect each COM terminal to its output terminal. Connect a separate load power supply. | Relay outputs are dry contacts that physically connect each COM terminal to its output terminal. Connect a separate load power supply. | ||
| Line 541: | Line 541: | ||
| | PWM6, PWM7, PWM8 | D6, D7, D8 | TIMER4 | ::: | | | PWM6, PWM7, PWM8 | D6, D7, D8 | TIMER4 | ::: | | ||
| - | PWM outputs use an 8bit duty value by default, with an output voltage of DC 0~5V. PWM2 and PWM3 share interrupt-input functions. | + | PWM outputs use an 8-bit duty value by default, with an output voltage of DC 0~5V. PWM2 and PWM3 share interrupt-input functions. |
| ==== Example program · PWM outputs ==== | ==== Example program · PWM outputs ==== | ||
| Line 829: | Line 829: | ||
| **Related built-in functions** | **Related built-in functions** | ||
| - | === Function example · LS Industrial Systems Cnet SLave: ICnetMem(), ICnetAdr(), ICnetInit(), | + | === Function example · LS Industrial Systems Cnet Slave: ICnetMem(), ICnetAdr(), ICnetInit(), |
| **Function prototype** | **Function prototype** | ||
en-us_products/mpino_8a8r.1791380126.txt.gz · Last modified: by 127.0.0.1
