en-us_products:mpino_8a8r_s [2026/09/14 23:56] – external edit 127.0.0.1en-us_products:mpino_8a8r_s [2026/10/25 08:42] (current) – external edit 127.0.0.1
Line 5: Line 5:
 Program the controller with Arduino IDE (Arduino C/C++) or MPINO STUDIO 2 (Arduino C/C++ & ladder logic). Program the controller with Arduino IDE (Arduino C/C++) or MPINO STUDIO 2 (Arduino C/C++ & ladder logic).
  
-See [[:en-us_guide:getting_started#mpino-8a8r_t_-s_first_upload|MPINO-8A8R(T)-S Arduino IDE getting started]] for installation, board and port selection, and your first upload.+See the [[:en-us_products:mpino_series#mpino_series_specifications|MPINO Series specifications]] for the board name, connection method, and first I/O numbers for MPINO-8A8R-S. 
 + 
 + 
 + 
  
 {{ :en-us_products:mpino-8a8r-s-connectors.svg?nolink |MPINO-8A8R-S connector guide }} {{ :en-us_products:mpino-8a8r-s-connectors.svg?nolink |MPINO-8A8R-S connector guide }}
Line 14: Line 18:
 |  Power  |  -  |  Supply voltage  | DC 12~24V (0.5A or more when using DC 24V)  | |  Power  |  -  |  Supply voltage  | DC 12~24V (0.5A or more when using DC 24V)  |
 |  Digital inputs  |  8 points \\ (Solid-state, isolated)  |  P0~P7  | operating input voltage: DC 0~40V \\ HIGH detection voltage: DC 5V or higher \\ 8 points/1COM \\ NPN/PNP input support  | |  Digital inputs  |  8 points \\ (Solid-state, isolated)  |  P0~P7  | operating input voltage: DC 0~40V \\ HIGH detection voltage: DC 5V or higher \\ 8 points/1COM \\ NPN/PNP input support  |
-|  Relay outputs  |  8 points \\ (Mechanical contacts, isolated)  |  R32~R39  | operating connection voltage: DC 0~30V or AC 0~250V \\ maximum allowable output current: 5A/1 points, 15A/1COM \\ 2 points/1COM × 4 groups  | +|  Relay outputs  |  8 points \\ (Mechanical contacts, isolated)  |  R32~R39  | operating connection voltage: DC 0~30V or AC 0~250V \\ maximum allowable output current: 5A/1 point, 15A/1COM \\ 2 points/1COM × 4 groups  | 
-|  Analog inputs  |  4 points \\ (Non-isolated)  |  A0~A3  | Standard input: 0(4)~20mA, 10bit \\ DC 0~5V: 10bit, input resistance 200kΩ \\ DC 0~10V: 10bit, input resistance 400kΩ; resistor-change option \\ current input resistance: 250Ω  |+|  Analog inputs  |  4 points \\ (Non-isolated)  |  A0~A3  | Standard input: 0(4)~20mA, 10-bit \\ DC 0~5V: 10-bit, input resistance 200kΩ \\ DC 0~10V: 10-bit, input resistance 400kΩ; resistor-change option \\ current input resistance: 250Ω  |
 |  Temperature sensor inputs  |  2 points \\ (Non-isolated)  |  A4, A5  | NTC 3950K, 10kΩ(25℃) \\ input temperature: -40~120℃ \\ Resolution: 0.1℃ (at 0~40℃)  | |  Temperature sensor inputs  |  2 points \\ (Non-isolated)  |  A4, A5  | NTC 3950K, 10kΩ(25℃) \\ input temperature: -40~120℃ \\ Resolution: 0.1℃ (at 0~40℃)  |
 |  High-speed input \\ Interrupts  |  4 points \\ (Non-isolated)  |  D18(SCL), D19(SDA) \\ D24(CLK), D25(DIO)  | input voltage: DC 0~5V \\ HIGH detection voltage: DC 3V or higher \\ maximum input frequency: 50kHz \\ D18/D19: 4.7kΩ pull-up; D24/D25: 4.7kΩ pull-down  | |  High-speed input \\ Interrupts  |  4 points \\ (Non-isolated)  |  D18(SCL), D19(SDA) \\ D24(CLK), D25(DIO)  | input voltage: DC 0~5V \\ HIGH detection voltage: DC 3V or higher \\ maximum input frequency: 50kHz \\ D18/D19: 4.7kΩ pull-up; D24/D25: 4.7kΩ pull-down  |
Line 24: Line 28:
 | ::: | ::: |  SRAM  | 4KB  | | ::: | ::: |  SRAM  | 4KB  |
 | ::: | ::: |  EEPROM  | 4KB  | | ::: | ::: |  EEPROM  | 4KB  |
 +
 +**Markdown file:** [[https://www.ilogics.net/docs/downloads:mpino:en:mpino_8a8r_s?do=export_raw|Download MPINO-8A8R-S.md]]
  
  
 ===== Digital inputs ===== ===== Digital inputs =====
  
 +[[:en-us_guide:wiring#digital_input_one_channel_check|See the one-channel digital-input check before wiring for the first time. →]]
 ^ Group ^ Terminal ^ Arduino Pin ^ Input Configuration ^ Terminals and Wiring Example ^ ^ Group ^ Terminal ^ Arduino Pin ^ Input Configuration ^ Terminals and Wiring Example ^
 | COM0 | P0~P7 | D0~D7 | 8 digital inputs, sharing COM0 |  {{:en-us_products:mpino-8a8r-s-digital-input.svg?628|MPINO-8A8R-S digital input terminals and NPN/PNP wiring}}  | | COM0 | P0~P7 | D0~D7 | 8 digital inputs, sharing COM0 |  {{:en-us_products:mpino-8a8r-s-digital-input.svg?628|MPINO-8A8R-S digital input terminals and NPN/PNP wiring}}  |
Line 149: Line 156:
 </code> </code>
  
 +
 +===== STATUS LED =====
 +
 +The MPINO-8A8R-S STATUS LED is an indicator mounted on the board. You can use it to show the operating state of your program.
 +
 +The STATUS LED is connected to digital pin D20. In a sketch, use ''LED_BUILTIN'' in place of D20. Set ''pinMode(LED_BUILTIN, OUTPUT)'' before controlling it. ''digitalWrite(LED_BUILTIN, HIGH)'' turns the LED on; ''digitalWrite(LED_BUILTIN, LOW)'' turns it off.
 +
 +**Note:** The STATUS LED is on the board and is separate from the external output terminals.
 +
 +==== Example · Blink the STATUS LED ====
 +
 +This example turns the STATUS LED on and off at 0.5-second intervals.
 +
 +<code cpp>
 +void setup() {
 +  pinMode(LED_BUILTIN, OUTPUT);
 +}
 +
 +void loop() {
 +  digitalWrite(LED_BUILTIN, HIGH);  // LED on
 +  delay(500);
 +  digitalWrite(LED_BUILTIN, LOW);   // LED off
 +  delay(500);
 +}
 +</code>
  
 ===== Relay outputs ===== ===== Relay outputs =====
  
 +[[:en-us_guide:wiring#relay_output_one_channel_check|See the one-channel relay-output check before wiring for the first time. →]]
 ^ Group ^ Terminal ^ Arduino Pin ^ Contact ratings ^ Terminals and Wiring Example ^ ^ Group ^ Terminal ^ Arduino Pin ^ Contact ratings ^ Terminals and Wiring Example ^
-| COM1 | R32, R33 | D32, D33 | AC 250V or DC 30V, Max. 5A/1 points·15A/COM |  {{:en-us_products:mpino-8a8r-s-relay-output.svg?492|MPINO-8A8R-S relay output terminals and load wiring}}  | +| COM1 | R32, R33 | D32, D33 | AC 250V or DC 30V, Max. 5A/1 point·15A/COM |  {{:en-us_products:mpino-8a8r-s-relay-output.svg?492|MPINO-8A8R-S relay output terminals and load wiring}}  | 
-| COM2 | R34, R35 | D34, D35 | AC 250V or DC 30V, Max. 5A/1 points·15A/COM | ::: | +| COM2 | R34, R35 | D34, D35 | AC 250V or DC 30V, Max. 5A/1 point·15A/COM | ::: | 
-| COM3 | R36, R37 | D36, D37 | AC 250V or DC 30V, Max. 5A/1 points·15A/COM | ::: | +| COM3 | R36, R37 | D36, D37 | AC 250V or DC 30V, Max. 5A/1 point·15A/COM | ::: | 
-| COM4 | R38, R39 | D38, D39 | AC 250V or DC 30V, Max. 5A/1 points·15A/COM | ::: |+| COM4 | R38, R39 | D38, D39 | AC 250V or DC 30V, Max. 5A/1 point·15A/COM | ::: |
  
 Relay outputs are dry contacts that physically connect each COM terminal to its output terminal. Connect a separate load power supply. Relay outputs are dry contacts that physically connect each COM terminal to its output terminal. Connect a separate load power supply.
Line 719: Line 752:
 **Related built-in functions** **Related built-in functions**
  
-=== Function example · LS Industrial Systems Cnet SLave: ICnetMem(), ICnetAdr(), ICnetInit(), ICnet() ===+=== Function example · LS Industrial Systems Cnet Slave: ICnetMem(), ICnetAdr(), ICnetInit(), ICnet() ===
  
 **Function prototype** **Function prototype**
Line 763: Line 796:
 </code> </code>
  
-[[:en-us_products:mpino_series|← MPINO Series comparison (Korean)]]+[[https://www.ilogics.net/en-us/products/mpino-8a8r-s|View MPINO-8A8R-S price and purchase options]]
  
 +[[:en-us_products:mpino_series|← MPINO Series comparison (Korean)]]
  
en-us_products/mpino_8a8r_s.1789397762.txt.gz · Last modified: by 127.0.0.1