User Tools

Site Tools


en-us_products:mpino_studio2:first_project

Differences

This shows you the differences between two versions of the page.

Link to this comparison view

Both sides previous revisionPrevious revision
en-us_products:mpino_studio2:first_project [2026/09/14 12:24] – external edit 127.0.0.1en-us_products:mpino_studio2:first_project [2026/10/03 13:15] (current) – external edit 127.0.0.1
Line 8: Line 8:
 {{ :en-us_products:mpino_studio2:first-project-flow.svg?1000 |Workflow from creating the first project to checking the running board }} {{ :en-us_products:mpino_studio2:first-project-flow.svg?1000 |Workflow from creating the first project to checking the running board }}
  
-> **About the screenshots:** The screenshots show the Korean interface. Button positions and keyboard shortcuts are the same as described below.+> **About the screenshots:** The screenshots show the English interface.
  
 ===== 1. Before You Begin ===== ===== 1. Before You Begin =====
Line 25: Line 25:
 MPINO Studio 2 opens **① an Untitled project** that you can edit immediately. The Explorer already contains **② the ''main'' code tab** and **③ the ''ladderLoop'' ladder tab**. MPINO Studio 2 opens **① an Untitled project** that you can edit immediately. The Explorer already contains **② the ''main'' code tab** and **③ the ''ladderLoop'' ladder tab**.
  
-{{ :products:mpino_studio2:first-run-window-marked.svg?1200 |Figure 1. Default project opened at first launch }}+{{ :en-us_products:mpino_studio2:first-run-window-marked.svg?1200 |Figure 1. Default project opened at first launch }}
  
 On the first launch, a notice about automatic error reporting appears once. Read the notice and select **OK** to close it. You can later change this option under **File → Preferences → General → Send error reports automatically**. On the first launch, a notice about automatic error reporting appears once. Read the notice and select **OK** to close it. You can later change this option under **File → Preferences → General → Send error reports automatically**.
  
-{{ :products:mpino_studio2:chfirst-run-notice.png?480 |Figure 2. Error-reporting notice displayed at first launch }}+{{ :en-us_products:mpino_studio2:chfirst-run-notice.png?480 |Figure 2. Error-reporting notice displayed at first launch }}
  
 ===== 3. Learn the Six Screen Areas ===== ===== 3. Learn the Six Screen Areas =====
Line 42: Line 42:
   - **⑥ Status bar:** Current status and port selector   - **⑥ Status bar:** Current status and port selector
  
-{{ :products:mpino_studio2:app-overview-layout-marked.svg?1200 |Figure 3. Main areas of the MPINO Studio 2 window }}+{{ :en-us_products:mpino_studio2:app-overview-layout-marked.svg?1200 |Figure 3. Main areas of the MPINO Studio 2 window }}
  
 **⑦ Ready** at the lower left is a static label. Use **⑧ Select Port** at the lower right to choose the serial port for uploading. **⑦ Ready** at the lower left is a static label. Use **⑧ Select Port** at the lower right to choose the serial port for uploading.
Line 56: Line 56:
   - Press ''Ctrl+S'' to save the pin map settings in the project.   - Press ''Ctrl+S'' to save the pin map settings in the project.
  
-{{ :products:mpino_studio2:board-select-modal-marked.svg?1100 |Figure 4. Board selection window with MPINO-8A4R(T)-S selected }}+{{ :en-us_products:mpino_studio2:board-select-modal-marked.svg?1100 |Figure 4. Board selection window with MPINO-8A4R(T)-S selected }}
  
 Selecting the board does not create a file on disk. The name and location of the ''.mp2'' project file are set when you save it. Selecting the board does not create a file on disk. The name and location of the ''.mp2'' project file are set when you save it.
Line 70: Line 70:
   - Confirm that your screen matches the figure below.   - Confirm that your screen matches the figure below.
  
-{{ :products:mpino_studio2:ladder-editor-toolbar-marked-phase1.svg?1200 |Figure 5. Ladder circuit with the P0 contact and P32 output coil }}+{{ :en-us_products:mpino_studio2:ladder-editor-toolbar-marked-phase1.svg?1200 |Figure 5. Ladder circuit with the P0 contact and P32 output coil }}
  
 Press ''Enter'' on **① the selected cell**, or double-click it, to open the edit window. Enter the value in **② the address field**, then choose **③ OK**. Contacts and coils use the same style of input window, so check the selected cell and address before confirming. Press ''Enter'' on **① the selected cell**, or double-click it, to open the edit window. Enter the value in **② the address field**, then choose **③ OK**. Contacts and coils use the same style of input window, so check the selected cell and address before confirming.
  
-{{ :products:mpino_studio2:ladder-cell-edit-modal-marked.svg?1050 |Figure 6. Entering P0 in the contact edit window }}+{{ :en-us_products:mpino_studio2:ladder-cell-edit-modal-marked.svg?1050 |Figure 6. Entering P0 in the contact edit window }}
  
 ==== Common Ladder Tools ==== ==== Common Ladder Tools ====
Line 116: Line 116:
   - The build succeeded if the final line contains **② ''[arduino-cli exit 0]''**.   - The build succeeded if the final line contains **② ''[arduino-cli exit 0]''**.
  
-{{ :products:mpino_studio2:build-output-panel-marked.svg?1200 |Figure 8. Build Output after a successful build }}+{{ :en-us_products:mpino_studio2:build-output-panel-marked.svg?1200 |Figure 8. Build Output after a successful build }}
  
 If the build fails, start with the error summary and the last part of the log. Check the selected board, cell addresses, and code syntax in that order. If the build fails, start with the error summary and the last part of the log. Check the selected board, cell addresses, and code syntax in that order.
Line 131: Line 131:
   - Confirm that the upload log continues below the build log and ends normally.   - Confirm that the upload log continues below the build log and ends normally.
  
-{{ :products:mpino_studio2:statusbar-port-picker-marked.svg?1200 |Figure 9. Selecting the upload port from the status bar }}+{{ :en-us_products:mpino_studio2:statusbar-port-picker-marked.svg?1200 |Figure 9. Selecting the upload port from the status bar }}
  
 The port list refreshes automatically when the drop-down opens. You can cancel an upload from the bottom panel while it is running. The port list refreshes automatically when the drop-down opens. You can cancel an upload from the bottom panel while it is running.
Line 141: Line 141:
 Select **① Serial Monitor** in the Activity bar. Choose **② the baud rate** and **③ character encoding**, then select **④ Connect**. Use **⑤ the ASCII/HEX control** to change the display mode, and check **⑥ the connection state** at the right. Select **① Serial Monitor** in the Activity bar. Choose **② the baud rate** and **③ character encoding**, then select **④ Connect**. Use **⑤ the ASCII/HEX control** to change the display mode, and check **⑥ the connection state** at the right.
  
-{{ :products:mpino_studio2:serial-monitor-panel-marked.svg?1200 |Figure 10. Connected Serial Monitor }}+{{ :en-us_products:mpino_studio2:serial-monitor-panel-marked.svg?1200 |Figure 10. Connected Serial Monitor }}
  
 ==== Real-Time Ladder Monitoring ==== ==== Real-Time Ladder Monitoring ====
Line 149: Line 149:
 When a physical input signal reaches P0, **② the P0 contact** and **③ the P32 coil** are highlighted. Press ''Esc'' to stop monitoring. When a physical input signal reaches P0, **② the P0 contact** and **③ the P32 coil** are highlighted. Press ''Esc'' to stop monitoring.
  
-{{ :products:mpino_studio2:ladder-live-monitoring-marked.svg?1200 |Figure 11. Real-time ladder monitoring with P0 and P32 energized }}+{{ :en-us_products:mpino_studio2:ladder-live-monitoring-marked.svg?1200 |Figure 11. Real-time ladder monitoring with P0 and P32 energized }}
  
 ===== 10. Phase 1 Shortcuts ===== ===== 10. Phase 1 Shortcuts =====
en-us_products/mpino_studio2/first_project.1789356278.txt.gz · Last modified: by 127.0.0.1

Donate Powered by PHP Valid HTML5 Valid CSS Driven by DokuWiki