en-us_products:mp_studio:first_project

Differences

This shows you the differences between two versions of the page.

Link to this comparison view

Next revision
Previous revision
en-us_products:mp_studio:first_project [2026/10/30 11:27] – created - external edit 127.0.0.1en-us_products:mp_studio:first_project [2026/11/12 20:37] (current) – external edit 127.0.0.1
Line 1: Line 1:
 ====== MP STUDIO 2 Phase 1 · Create Your First Project ====== ====== MP STUDIO 2 Phase 1 · Create Your First Project ======
- 
-[[products:mp_studio:first_project|한국어]] | **English** 
  
 This page is for first-time users of MP STUDIO 2. You will select a model in a new project, create **a rung in which output P32 turns ON when input P0 is ON**, and then save it, set up communication, download it and monitor it. This page is for first-time users of MP STUDIO 2. You will select a model in a new project, create **a rung in which output P32 turns ON when input P0 is ON**, and then save it, set up communication, download it and monitor it.
Line 8: Line 6:
 | MP STUDIO 2 | MPS-8A8R(T)-S | ''P0'' NO contact → ''P32'' output coil | | MP STUDIO 2 | MPS-8A8R(T)-S | ''P0'' NO contact → ''P32'' output coil |
  
-{{ :en-us_products:mp_studio:first-project-flow.svg?1000 |Workflow from creating the first project to checking it on the device }}+{{ :en-us_products:mp_studio:first-project-flow.svg?1000 |Workflow from creating the first project to checking it on the PLC }}
  
 ===== 1. Before You Start ===== ===== 1. Before You Start =====
Line 15: Line 13:
  
   * A PC with MP STUDIO 2 installed   * A PC with MP STUDIO 2 installed
-  * One MPS or MPA series device +  * One MPS or MPA series PLC 
-  * The download cable and driver for your device (see the product tables on the [[:en-us_products:mps|MPS Series]] and [[:en-us_products:mpa|MPA Series]] pages)+  * The download cable and driver for your PLC (see the product tables on the [[:en-us_products:mps|MPS Series]] and [[:en-us_products:mpa|MPA Series]] pages)
  
-We recommend disconnecting the output loads the first time, while you write and download the program. If you do not have a device, you can run the same circuit on your PC with [[:en-us_products:mp_studio:simulation|Phase 8 · Simulation]].+We recommend disconnecting the output loads the first time, while you write and download the program. If you do not have a PLC, you can run the same circuit on your PC with [[:en-us_products:mp_studio:simulation|Phase 8 · Simulation]].
  
 ===== 2. The First Screen ===== ===== 2. The First Screen =====
  
-When the program starts, **① an empty ladder** opens. The top band has **② the file and tool buttons** and **③ the device pill**, and the row below it has **④ the menus** and **⑤ the program tabs**. Choose contacts and coils from **⑥ the symbol rail** on the left, and check the selected cell in **⑦ the Inspector** on the right.+When the program starts, **① an empty ladder** opens. The top band has **② the file and tool buttons** and **③ the PLC status indicator**, and the row below it has **④ the menus** and **⑤ the program tabs**. Choose contacts and coils from **⑥ the symbol rail** on the left, and check the selected cell in **⑦ the Inspector** on the right.
  
 {{ :en-us_products:mp_studio:start-empty-marked.svg?1200 |Figure 1. The empty ladder that opens at first launch }} {{ :en-us_products:mp_studio:start-empty-marked.svg?1200 |Figure 1. The empty ladder that opens at first launch }}
Line 33: Line 31:
  
   - Select **Project → New Project** or press ''Ctrl+N''. If you have unsaved changes, choose whether to save them in the confirmation window.   - Select **Project → New Project** or press ''Ctrl+N''. If you have unsaved changes, choose whether to save them in the confirmation window.
-  - Select **Setting → Device** or click the **Devices** button in the top band to open the **Device Select** window.+  - Select **Settings → Device** or click the **Device** button in the top band to open the **Device Select** window.
   - Under **① the series buttons**, select ''MPS''.   - Under **① the series buttons**, select ''MPS''.
   - Under **② Model**, select ''MPS-8A8R(T)-S''.   - Under **② Model**, select ''MPS-8A8R(T)-S''.
-  - Check that **③ Device Name** and **④ P Area** have changed to the selected model, and click **⑤ OK**.+  - Check that **③ Device name** and **④ P area** have changed to the selected model, and click **⑤ OK**.
  
 {{ :en-us_products:mp_studio:device-select-marked.svg?700 |Figure 2. The Device Select window with MPS-8A8R(T)-S selected }} {{ :en-us_products:mp_studio:device-select-marked.svg?700 |Figure 2. The Device Select window with MPS-8A8R(T)-S selected }}
Line 42: Line 40:
 When you change the series, the option **Reset the data memory sizes to this model's defaults.** appears. If you check it, the memory area sizes change to the defaults of the new model; if you leave it unchecked, the current settings are kept. When you change the series, the option **Reset the data memory sizes to this model's defaults.** appears. If you check it, the memory area sizes change to the defaults of the new model; if you leave it unchecked, the current settings are kept.
  
-A new project takes over the model setting of the previous project. Check the model shown in the device pill in the top band to make sure it matches your actual device. Changing the model also changes the available I/O addresses and memory sizes.+A new project takes over the model setting of the previous project. Check the model shown in the PLC status indicator in the top band to make sure it matches your actual PLC. Changing the model also changes the available I/O addresses and memory sizes.
  
 ===== 4. Placing the P0 Contact and P32 Coil ===== ===== 4. Placing the P0 Contact and P32 Coil =====
Line 65: Line 63:
  
   - Select **Project → Save Project** or press ''Ctrl+S''.   - Select **Project → Save Project** or press ''Ctrl+S''.
-  - The first time you save, choose the location and file name in the window that opens. The project is saved as an ''.mpl'' file.+  - The first time you save, choose the location and file name in the window that opens. The project is saved as an ''.mpx'' file.
   - Check that the document name in the top band has changed to the file name you saved.   - Check that the document name in the top band has changed to the file name you saved.
  
Line 72: Line 70:
 ===== 6. Communication Port Setup ===== ===== 6. Communication Port Setup =====
  
-  - Connect the device to the PC with the download cable, and check the COM number under **Device Manager → Ports (COM & LPT)** in Windows. If the port does not appear, install the driver listed in the product table and reconnect the cable. +  - Connect the PLC to the PC with the download cable, and check the COM number under **Device Manager → Ports (COM & LPT)** in Windows. If the port does not appear, install the driver listed in the product table and reconnect the cable. 
-  - Select **Setting → Communication Port** or click the **Communication** button in the top band.+  - Select **Settings → Communication Port** or click the **Communication** button in the top band.
   - Under **① Channel**, select the COM port you found. If it is not in the list, click **② Refresh port list** on the right to read the port list again.   - Under **① Channel**, select the COM port you found. If it is not in the list, click **② Refresh port list** on the right to read the port list again.
   - Click **③ OK** to save the setting.   - Click **③ OK** to save the setting.
  
-{{ :en-us_products:mp_studio:port-dialog-com-marked.svg?640 |Figure 5. Selecting the download channel in the Communication Setting window }}+{{ :en-us_products:mp_studio:port-dialog-com-marked.svg?640 |Figure 5. Selecting the download channel in the Communication Port window }}
  
 The communication port setting is saved with the project. Ethernet connections and the serial channel modes are described in [[:en-us_products:mp_studio:download|Phase 6]]. The communication port setting is saved with the project. Ethernet connections and the serial channel modes are described in [[:en-us_products:mp_studio:download|Phase 6]].
Line 84: Line 82:
  
   - Click **Download** on the right of the top band or select **Run → Download**. The shortcut is ''Ctrl+T''.   - Click **Download** on the right of the top band or select **Run → Download**. The shortcut is ''Ctrl+T''.
-  - The program check, conversion to device code, the device firmware version check and the transfer run in turn, and the progress is shown in a progress window. +  - The program check, conversion to PLC code, the PLC firmware version check and the transfer run in turn, and the progress is shown in a progress window. 
-  - Do not turn off the device or disconnect the cable during the transfer.+  - Do not turn off the PLC or disconnect the cable during the transfer.
   - The download has finished when the **Download complete** window appears. Click **Monitoring** in this window to start monitoring right away.   - The download has finished when the **Download complete** window appears. Click **Monitoring** in this window to start monitoring right away.
  
 {{ :en-us_products:mp_studio:download-flow.svg?1000 |Figure 6. Download sequence }} {{ :en-us_products:mp_studio:download-flow.svg?1000 |Figure 6. Download sequence }}
  
-> **Caution:** ''Ctrl+T'' downloads the program to the device immediately, without a confirmation window. First make sure the communication port is the device you intend to connect to.+> **Caution:** ''Ctrl+T'' downloads the program to the PLC immediately, without a confirmation window. First make sure the communication port is connected to the PLC you intend to use.
  
 ===== 8. Checking Operation with Monitoring ===== ===== 8. Checking Operation with Monitoring =====
  
   - Click **Monitoring** in the top band or press ''Ctrl+M''.   - Click **Monitoring** in the top band or press ''Ctrl+M''.
-  - Check that **① the device pill** shows the monitoring state and the scan time (SCAN).+  - Check that **① the PLC status indicator** shows the monitoring state and the scan time (SCAN).
   - When a signal arrives at P0, **② the P0 contact** changes to the power-flow color, and when P32 turns on, **③ the P32 self-holding contact** and the P32 coil are also shown in the power-flow color.   - When a signal arrives at P0, **② the P0 contact** changes to the power-flow color, and when P32 turns on, **③ the P32 self-holding contact** and the P32 coil are also shown in the power-flow color.
   - To stop monitoring, press ''Esc'' or ''Ctrl+M''.   - To stop monitoring, press ''Esc'' or ''Ctrl+M''.
Line 101: Line 99:
 {{ :en-us_products:mp_studio:monitor-p0-p32-marked.svg?1200 |Figure 7. The ladder with input P0 ON and P32 in the power-flow color (the bundled example running in simulation) }} {{ :en-us_products:mp_studio:monitor-p0-p32-marked.svg?1200 |Figure 7. The ladder with input P0 ON and P32 in the power-flow color (the bundled example running in simulation) }}
  
-Figure 7 shows the bundled example (**Project → Open Example**) running in [[:en-us_products:mp_studio:simulation|simulation]]. Monitoring a real device uses the same colors, and the device pill shows **Monitoring · port**.+Figure 7 shows the bundled example (**Project → Open Example**) running in [[:en-us_products:mp_studio:simulation|simulation]]. Monitoring a real PLC uses the same colors, and the PLC status indicator shows **Monitoring · port**.
  
 ===== 9. First Project Shortcuts ===== ===== 9. First Project Shortcuts =====
Line 118: Line 116:
 You have completed Phase 1 when all of the following are true: You have completed Phase 1 when all of the following are true:
  
-  * The model matches your actual device.+  * The model matches your actual PLC.
   * The first rung has a ''P0'' contact and a ''P32'' coil, and there are no red cells.   * The first rung has a ''P0'' contact and a ''P32'' coil, and there are no red cells.
-  * The ''.mpl'' project has been saved.+  * The ''.mpx'' project has been saved.
   * You have seen the Download complete window.   * You have seen the Download complete window.
   * The monitoring display of the P32 coil changes with the P0 input.   * The monitoring display of the P32 coil changes with the P0 input.
Line 132: Line 130:
 | ''MPS-16A8R(T)-R2'' | ''P0'' | ''P20'' | | ''MPS-16A8R(T)-R2'' | ''P0'' | ''P20'' |
  
-For the I/O addresses of your model, see [[:en-us_products:mp_studio:memory_symbols|Phase 5 · Memory and Symbols]] and the product page.+For the I/O addresses of your model, see [[:en-us_products:mp_studio:memory_symbols|Phase 5 · Memory and Symbols]] and the product pages.
  
 ===== Related Pages ===== ===== Related Pages =====
en-us_products/mp_studio/first_project.1793327273.txt.gz · Last modified: by 127.0.0.1