| Line 6: | Line 6: | ||
| | MP STUDIO 2 | MPS-8A8R(T)-S | '' | | MP STUDIO 2 | MPS-8A8R(T)-S | '' | ||
| - | {{ : | + | {{ : |
| ===== 1. Before You Start ===== | ===== 1. Before You Start ===== | ||
| Line 13: | Line 13: | ||
| * A PC with MP STUDIO 2 installed | * A PC with MP STUDIO 2 installed | ||
| - | * One MPS or MPA series | + | * One MPS or MPA series |
| - | * The download cable and driver for your device | + | * The download cable and driver for your PLC (see the product tables on the [[: |
| - | We recommend disconnecting the output loads the first time, while you write and download the program. If you do not have a device, you can run the same circuit on your PC with [[: | + | We recommend disconnecting the output loads the first time, while you write and download the program. If you do not have a PLC, you can run the same circuit on your PC with [[: |
| ===== 2. The First Screen ===== | ===== 2. The First Screen ===== | ||
| - | When the program starts, **① an empty ladder** opens. The top band has **② the file and tool buttons** and **③ the device pill**, and the row below it has **④ the menus** and **⑤ the program tabs**. Choose contacts and coils from **⑥ the symbol rail** on the left, and check the selected cell in **⑦ the Inspector** on the right. | + | When the program starts, **① an empty ladder** opens. The top band has **② the file and tool buttons** and **③ the PLC status indicator**, and the row below it has **④ the menus** and **⑤ the program tabs**. Choose contacts and coils from **⑥ the symbol rail** on the left, and check the selected cell in **⑦ the Inspector** on the right. |
| {{ : | {{ : | ||
| Line 31: | Line 31: | ||
| - Select **Project → New Project** or press '' | - Select **Project → New Project** or press '' | ||
| - | - Select **Setting | + | - Select **Settings |
| - Under **① the series buttons**, select '' | - Under **① the series buttons**, select '' | ||
| - Under **② Model**, select '' | - Under **② Model**, select '' | ||
| - | - Check that **③ Device | + | - Check that **③ Device |
| {{ : | {{ : | ||
| Line 40: | Line 40: | ||
| When you change the series, the option **Reset the data memory sizes to this model' | When you change the series, the option **Reset the data memory sizes to this model' | ||
| - | A new project takes over the model setting of the previous project. Check the model shown in the device pill in the top band to make sure it matches your actual | + | A new project takes over the model setting of the previous project. Check the model shown in the PLC status indicator |
| ===== 4. Placing the P0 Contact and P32 Coil ===== | ===== 4. Placing the P0 Contact and P32 Coil ===== | ||
| Line 70: | Line 70: | ||
| ===== 6. Communication Port Setup ===== | ===== 6. Communication Port Setup ===== | ||
| - | - Connect the device | + | - Connect the PLC to the PC with the download cable, and check the COM number under **Device Manager → Ports (COM & LPT)** in Windows. If the port does not appear, install the driver listed in the product table and reconnect the cable. |
| - | - Select **Setting | + | - Select **Settings |
| - Under **① Channel**, select the COM port you found. If it is not in the list, click **② Refresh port list** on the right to read the port list again. | - Under **① Channel**, select the COM port you found. If it is not in the list, click **② Refresh port list** on the right to read the port list again. | ||
| - Click **③ OK** to save the setting. | - Click **③ OK** to save the setting. | ||
| - | {{ : | + | {{ : |
| The communication port setting is saved with the project. Ethernet connections and the serial channel modes are described in [[: | The communication port setting is saved with the project. Ethernet connections and the serial channel modes are described in [[: | ||
| Line 82: | Line 82: | ||
| - Click **Download** on the right of the top band or select **Run → Download**. The shortcut is '' | - Click **Download** on the right of the top band or select **Run → Download**. The shortcut is '' | ||
| - | - The program check, conversion to device | + | - The program check, conversion to PLC code, the PLC firmware version check and the transfer run in turn, and the progress is shown in a progress window. |
| - | - Do not turn off the device | + | - Do not turn off the PLC or disconnect the cable during the transfer. |
| - The download has finished when the **Download complete** window appears. Click **Monitoring** in this window to start monitoring right away. | - The download has finished when the **Download complete** window appears. Click **Monitoring** in this window to start monitoring right away. | ||
| {{ : | {{ : | ||
| - | > **Caution: | + | > **Caution: |
| ===== 8. Checking Operation with Monitoring ===== | ===== 8. Checking Operation with Monitoring ===== | ||
| - Click **Monitoring** in the top band or press '' | - Click **Monitoring** in the top band or press '' | ||
| - | - Check that **① the device pill** shows the monitoring state and the scan time (SCAN). | + | - Check that **① the PLC status indicator** shows the monitoring state and the scan time (SCAN). |
| - When a signal arrives at P0, **② the P0 contact** changes to the power-flow color, and when P32 turns on, **③ the P32 self-holding contact** and the P32 coil are also shown in the power-flow color. | - When a signal arrives at P0, **② the P0 contact** changes to the power-flow color, and when P32 turns on, **③ the P32 self-holding contact** and the P32 coil are also shown in the power-flow color. | ||
| - To stop monitoring, press '' | - To stop monitoring, press '' | ||
| Line 99: | Line 99: | ||
| {{ : | {{ : | ||
| - | Figure 7 shows the bundled example (**Project → Open Example**) running in [[: | + | Figure 7 shows the bundled example (**Project → Open Example**) running in [[: |
| ===== 9. First Project Shortcuts ===== | ===== 9. First Project Shortcuts ===== | ||
| Line 116: | Line 116: | ||
| You have completed Phase 1 when all of the following are true: | You have completed Phase 1 when all of the following are true: | ||
| - | * The model matches your actual | + | * The model matches your actual |
| * The first rung has a '' | * The first rung has a '' | ||
| * The '' | * The '' | ||
| Line 130: | Line 130: | ||
| | '' | | '' | ||
| - | For the I/O addresses of your model, see [[: | + | For the I/O addresses of your model, see [[: |
| ===== Related Pages ===== | ===== Related Pages ===== | ||