en-us_products:mp_studio:menus_settings
Differences
This shows you the differences between two versions of the page.
| Both sides previous revisionPrevious revisionNext revision | Previous revision | ||
| en-us_products:mp_studio:menus_settings [2026/11/05 12:39] – external edit 127.0.0.1 | en-us_products:mp_studio:menus_settings [2026/11/12 20:37] (current) – external edit 127.0.0.1 | ||
|---|---|---|---|
| Line 29: | Line 29: | ||
| ^ Item ^ Shortcut ^ Action ^ | ^ Item ^ Shortcut ^ Action ^ | ||
| | Show Symbols · Show Comments | — | Shows symbol names and comments on the cells. | | | Show Symbols · Show Comments | — | Shows symbol names and comments on the cells. | | ||
| - | | Bookmark List | — | Shows or hides the bookmark | + | | Bookmark List | — | Shows or hides the bookmark list at the bottom of the Functions panel. | |
| - | | Symbol Rail · Functions · Inspector · Watch · Command Bar · Status | + | | Symbol Rail · Functions · Inspector · Watch · Command Bar · Status |
| | Hide All Panels | '' | | Hide All Panels | '' | ||
| | Zoom In · Zoom Out · Fit to Width | '' | | Zoom In · Zoom Out · Fit to Width | '' | ||
| Line 48: | Line 48: | ||
| | Data Table | — | [[: | | Data Table | — | [[: | ||
| | Program Memory | — | [[: | | Program Memory | — | [[: | ||
| - | | FORCE INPUT / OUTPUT | + | | Force Input/Output |
| | Clear EEPROM | — | [[: | | Clear EEPROM | — | [[: | ||
| - | | Set Device | + | | Set PLC Clock… | — | [[: |
| | Mnemonic | — | [[: | | Mnemonic | — | [[: | ||
| - | ===== Setting | + | ===== Settings |
| - | {{ : | + | {{ : |
| Line 61: | Line 61: | ||
| | Communication Port | Sets the download channel and the serial channels. [[: | | Communication Port | Sets the download channel and the serial channels. [[: | ||
| | 언어: 한국어 · Language: English · 言語: 日本語 | Changes the display language. | | | 언어: 한국어 · Language: English · 言語: 日本語 | Changes the display language. | | ||
| - | | Option | + | | Options |
| | Data Memory | Sets the memory area sizes and retentive ranges. [[: | | Data Memory | Sets the memory area sizes and retentive ranges. [[: | ||
| | Symbol | Opens the symbol table. [[: | | Symbol | Opens the symbol table. [[: | ||
| - | | LCD Screen Editor | Creates screens to show on a character LCD. The ladder shows a screen with the '' | + | | CLCD Screen Editor | Creates screens to show on a character LCD. The ladder shows a screen with the '' |
| + | | 7-Segment Screen Editor | Creates screens to show on a 7-segment display. The ladder shows a screen with the '' | ||
| | Device | Selects the model and expansion modules. [[: | | Device | Selects the model and expansion modules. [[: | ||
| | Modbus RTU Master | Sets up Modbus RTU master communication. [[: | | Modbus RTU Master | Sets up Modbus RTU master communication. [[: | ||
| - | | RTC (Clock)… | Sets the start address of the D area (16 words) where the device | + | | RTC (Clock)… | Sets the start address of the D area (16 words) where the PLC writes the date, time and status of an external DS3231 module every 0.1 seconds. [[: |
| + | | Input Filter… | Sets the time used to filter out chatter and noise on digital inputs, as a default and as per-input values (V1.4.0 and later). [[: | ||
| + | | User Protocol… | Defines, per communication port, the frames and transactions to exchange with devices that do not use Modbus (V1.3.0 and later). [[: | ||
| | Theme: Modern Dark · VS Code · Light | Changes the screen theme. | | | Theme: Modern Dark · VS Code · Light | Changes the screen theme. | | ||
| ===== Options ===== | ===== Options ===== | ||
| - | Select **Setting | + | Select **Settings |
| - | {{ : | + | {{ : |
| * **① Search settings:** finds items by setting name. | * **① Search settings:** finds items by setting name. | ||
| - | * **② Navigation: | + | * **② Navigation: |
| * **③ Settings area** | * **③ Settings area** | ||
| * **④ Preview:** changed settings are reflected in the ladder preview right away. | * **④ Preview:** changed settings are reflected in the ladder preview right away. | ||
| Line 83: | Line 86: | ||
| ^ Navigation ^ Settings ^ | ^ Navigation ^ Settings ^ | ||
| - | | Grid | Cell width and height | + | | Grid & duplicate coils | Cell size (Cell width, |
| - | | FONT | Grid Font (addresses, symbols, comments and monitor values), Header | + | | FONT | Grid font (addresses, symbols, comments and monitor values), Header |
| | COLOR | Colors for the Theme, Ladder, Function blocks, Monitor & check, and Interface | | | COLOR | Colors for the Theme, Ladder, Function blocks, Monitor & check, and Interface | | ||
| | Brand name | The name shown in the window title | | | Brand name | The name shown in the window title | | ||
| - | Columns | + | Cells per row, Check for duplicate coils and Timer base apply only to the project. Custom colors apply to every theme, and colors you leave unset follow the selected theme. Printing always uses paper colors (black). |
| {{ : | {{ : | ||
| + | |||
| + | ==== Timer Base ==== | ||
| + | |||
| + | In **Grid & duplicate coils**, use **Timer base** to choose the time unit that timers and clocks ('' | ||
| + | |||
| + | ^ Item ^ 10 ms (default) ^ 1 ms ^ | ||
| + | | Set value written as a number only ('' | ||
| + | | Set value with a unit ('' | ||
| + | | '' | ||
| + | | '' | ||
| + | | Longest timer time ('' | ||
| + | |||
| + | Even with 1 ms, timers check the time once per scan, so the real resolution cannot be finer than the scan time. You do not need to change the PLC firmware. Values written as ×10 ms (the timeout of the Modbus RTU Master and the EEPROM update cycle of Data Memory) and SCAN TIME stay in 10 ms units regardless of the timer base. The 1 ms base uses 5 more bytes of PLC RAM, and if there is not enough RAM, a compile error is shown. | ||
| + | |||
| + | When you change the base and click **OK** (or **Apply**), the **Change timer base** window shows the number of affected cells, if there are any. | ||
| + | |||
| + | * **Adjust values too (keep the same time):** changes the timer set values and clock numbers written as numbers so that the times stay the same. From 10 ms to 1 ms they are multiplied by 10; from 1 ms to 10 ms they are divided by 10 (the remainder is dropped, and a result below 1 becomes 1). | ||
| + | * **Keep numbers:** changes only the base. The times become 1/10 when you go from 10 ms to 1 ms, and 10 times longer when you go from 1 ms to 10 ms. | ||
| + | * **Cancel:** returns to the Options window without changing the base. | ||
| + | |||
| + | Timer set values written as variables, cells that read the current value of a timer, and timer cells that will go out of range (red) after the change are counted separately in the window, so check them yourself. A single '' | ||
| ===== Themes and Language ===== | ===== Themes and Language ===== | ||
| - | In the **Setting** menu, choose **Theme: Modern Dark**, **Theme: VS Code** or **Theme: Light**. | + | In the **Settings** menu, choose **Theme: Modern Dark**, **Theme: VS Code** or **Theme: Light**. |
| {{ : | {{ : | ||
| - | Use **언어: 한국어**, | + | Use **언어: 한국어**, |
| - | {{ : | + | {{ : |
| ===== Printing ===== | ===== Printing ===== | ||
| Line 110: | Line 134: | ||
| ===== Modbus RTU Master ===== | ===== Modbus RTU Master ===== | ||
| - | Select **Setting | + | Select **Settings |
| - | {{ : | + | {{ : |
| - | - In **① Communication Port**, choose the channel to use as the master (**Comm Port 1** to **Comm Port 3**), and set the Baud Rate, Data Bits, Stop Bits, Parity, Timeout (×10 ms) and Delay (ms). | + | - In **① Communication Port**, choose the channel to use as the master (**Comm Port 1** to **Comm Port 3**), and set the Baud rate, Data bits, Stop bits, Parity, Timeout (×10 ms) and Delay (ms). |
| - Click **② Add** to add an item. **Sort** sorts the items. | - Click **② Add** to add an item. **Sort** sorts the items. | ||
| - | - In **③ the item table**, enter the **Modbus Code** (for example '' | + | - In **③ the item table**, enter the **Function code** (for example '' |
| - Click **OK** to save. | - Click **OK** to save. | ||
| Line 125: | Line 149: | ||
| ===== Autosave and Recovery ===== | ===== Autosave and Recovery ===== | ||
| - | MP STUDIO 2 automatically saves the project you are editing. If the program closed without saving, the **Recover | + | MP STUDIO 2 automatically saves the project you are editing. If the program closed without saving, the **Recover |
| * **Yes:** opens the autosaved copy. | * **Yes:** opens the autosaved copy. | ||
| - | * **No:** deletes the autosaved copy. | + | * **Delete:** deletes the autosaved copy. |
| * **Cancel:** keeps the autosaved copy without deleting it. You can open it later from **Project → Recover Autosave…**. | * **Cancel:** keeps the autosaved copy without deleting it. You can open it later from **Project → Recover Autosave…**. | ||
| - | {{ : | + | {{ : |
| ===== Help Menu ===== | ===== Help Menu ===== | ||
| Line 140: | Line 164: | ||
| | About MP STUDIO 2 | Shows the program version and information. | | | About MP STUDIO 2 | Shows the program version and information. | | ||
| | Homepage | Opens the ILOGICS homepage. | | | Homepage | Opens the ILOGICS homepage. | | ||
| - | | SW Manual | Opens the software manual. | | + | | Software |
| - | | HW Manual | Opens the hardware manual of the selected model. | | + | | Hardware |
| - | | Report a Problem… | Describe | + | | Report a Problem… | Describes |
| | Request an Improvement… | Sends a feature you would like or an improvement to the developer. | | | Request an Improvement… | Sends a feature you would like or an improvement to the developer. | | ||
| | Send Error Reports Automatically | When checked (✓), diagnostic information is sent automatically when an error occurs. | | | Send Error Reports Automatically | When checked (✓), diagnostic information is sent automatically when an error occurs. | | ||
en-us_products/mp_studio/menus_settings.1793849997.txt.gz · Last modified: by 127.0.0.1
