en-us_products:mp_studio:modbus_device_table
Differences
This shows you the differences between two versions of the page.
| en-us_products:mp_studio:modbus_device_table [2026/11/05 12:39] – created - external edit 127.0.0.1 | en-us_products:mp_studio:modbus_device_table [2026/11/12 20:37] (current) – external edit 127.0.0.1 | ||
|---|---|---|---|
| Line 1: | Line 1: | ||
| ====== MP STUDIO 2 · Modbus Device Table ====== | ====== MP STUDIO 2 · Modbus Device Table ====== | ||
| - | The device table sets out, in a table for each device, | + | The device table organizes |
| {{ : | {{ : | ||
| Line 7: | Line 7: | ||
| ===== Opening the Device Table ===== | ===== Opening the Device Table ===== | ||
| - | Select **Setting | + | Select **Settings |
| - | If a port is set to **Modbus RTU Master** in the **Communication | + | If a port is set to **Modbus RTU Master** in the **Communication |
| ===== Window Layout ===== | ===== Window Layout ===== | ||
| Line 17: | Line 17: | ||
| ^ Item ^ Description ^ | ^ Item ^ Description ^ | ||
| | Port | Chooses the communication port (Comm Port 1 to Comm Port 3) used for the device table. The number of devices registered on each port is shown with it. | | | Port | Chooses the communication port (Comm Port 1 to Comm Port 3) used for the device table. The number of devices registered on each port is shown with it. | | ||
| - | | Baud | The communication settings of that port. Click it to open the **Communication | + | | Baud rate | The communication settings of that port. Click it to open the **Communication |
| | Cycle | The estimated time to go once through the polled reads and writes. | | | Cycle | The estimated time to go once through the polled reads and writes. | | ||
| - | | RAM · Flash | The memory the device table uses on the device. "(old method about N KB)" is the size the same content would take with the old list method. | | + | | RAM · Flash | The memory the device table uses on the PLC. "(old method about N KB)" is the size the same content would take with the old list method. | |
| When you click OK, the selected port changes to **Modbus RTU Master** and download on that port is turned off. If you choose a port that is not a master yet, this notice is shown at the top of the window. | When you click OK, the selected port changes to **Modbus RTU Master** and download on that port is turned off. If you choose a port that is not a master yet, this notice is shown at the top of the window. | ||
| Line 30: | Line 30: | ||
| | Name | Device N | A name for display. | | | Name | Device N | A name for display. | | ||
| | Slave ID | An unused number | 0 to 247. It must not be the same as another device on the same port. 0 is broadcast (write only). | | | Slave ID | An unused number | 0 to 247. It must not be the same as another device on the same port. 0 is broadcast (write only). | | ||
| - | | Reply wait (ms) | 100 | 20 to 60000. How long to wait for a reply. | | + | | Response timeout |
| | Retries | 2 | 0 to 10. How many times to send again when there is no reply. | | | Retries | 2 | 0 to 10. How many times to send again when there is no reply. | | ||
| | Recheck interval (s) | 5 | 1 to 3600. A device that still does not reply after the retries is skipped and checked again at this interval. | | | Recheck interval (s) | 5 | 1 to 3600. A device that still does not reply after the retries is skipped and checked again at this interval. | | ||
| | Word order | Low word first (CDAB) | The word and byte order of 2-word (32-bit) values. | | | Word order | Low word first (CDAB) | The word and byte order of 2-word (32-bit) values. | | ||
| - | | Max read at once | Auto | The largest number of values read in one transaction. Leave it empty to have it set to suit the model. | | + | | Max read size | Auto | The largest number of values read in one transaction. Leave it empty to have it set to suit the model. | |
| | Extra wait (ms) | 0 | 0 to 10000. Additional time to wait between transactions. | | | Extra wait (ms) | 0 | 0 to 10000. Additional time to wait between transactions. | | ||
| | Status word | Empty (not used) | The word address that receives the device status. Click **Auto** to pick a free D word. | | | Status word | Empty (not used) | The word address that receives the device status. Click **Auto** to pick a free D word. | | ||
| Line 49: | Line 49: | ||
| | Device address | The address on the other device (0 to 65535). | | | Device address | The address on the other device (0 to 65535). | | ||
| | Count | 1 means a single value; 2 or more means a range starting at the PLC address. | | | Count | 1 means a single value; 2 or more means a range starting at the PLC address. | | ||
| - | | PLC address | The device | + | | PLC address | The PLC memory that exchanges the value (for example '' |
| - | | Type | The data type, set by the PLC address. | | + | | Data type | The data type, set by the PLC address. | |
| | Description | A note. | | | Description | A note. | | ||
| | Trigger | Leave it empty to poll. Enter 1 to 255 to send the line only when '' | | Trigger | Leave it empty to poll. Enter 1 to 255 to send the line only when '' | ||
| Line 57: | Line 57: | ||
| Click **+ Add line** to add a line. To enter several lines at once, copy them from Excel in the order " | Click **+ Add line** to add a line. To enter several lines at once, copy them from Excel in the order " | ||
| - | **Frames actually sent** at the bottom of the window lists, in order, the transactions the device | + | **Frames actually sent** at the bottom of the window lists, in order, the transactions the PLC actually sends. The very bottom shows the number of transactions compared with the old list method, such as "N values: old method N round trips → table M". Click **OK** to apply the changes. Save the project to keep them in the file. |
| ===== Reading and Writing ===== | ===== Reading and Writing ===== | ||
| - | * **Reading: | + | * **Reading: |
| - | * **Order:** the devices are communicated | + | * **Order:** the PLC communicates |
| * **Writing: | * **Writing: | ||
| - | * **When there is no reply:** the request is sent again as many times as the retries, and if there is still no reply, that device is skipped and checked again at every recheck interval. | + | * **When there is no reply:** the request is sent again as many times as the Retries setting, and if there is still no reply, that device is skipped and checked again at every recheck interval. |
| ===== Triggered Sending (MBTRIG) ===== | ===== Triggered Sending (MBTRIG) ===== | ||
| Line 73: | Line 73: | ||
| - If you want the ladder to know when sending has finished, enter a bit address (for example '' | - If you want the ladder to know when sending has finished, enter a bit address (for example '' | ||
| - Click **OK**. | - Click **OK**. | ||
| - | - Add an '' | + | - Add an '' |
| {{ : | {{ : | ||
| Line 105: | Line 105: | ||
| | ✕ Not connected | The device is not connected. | | | ✕ Not connected | The device is not connected. | | ||
| - | A gray ○ means the status shown cannot be trusted, for example because the program on the device | + | A gray ○ means the status shown cannot be trusted, for example because the program on the PLC differs from this project or the PLC is not responding, and the reason is shown with it. ― marks a device without a status word. |
| ===== Simulation ===== | ===== Simulation ===== | ||
| Line 120: | Line 120: | ||
| * A port used by the device table must be set to **Modbus RTU Master** with **Use this channel for download** turned off. Clicking OK in the device table sets the port this way. | * A port used by the device table must be set to **Modbus RTU Master** with **Use this channel for download** turned off. Clicking OK in the device table sets the port this way. | ||
| - | * If the device | + | * If the PLC does not have enough RAM, the program cannot be compiled. Reduce the number of devices or lines, or reduce the memory area sizes. |
| - | * If receiving cells overlap the [[: | + | * If the receiving cells overlap the [[: |
| * The device table is saved in the project file ('' | * The device table is saved in the project file ('' | ||