en-us_products:mp_studio:monitoring

Differences

This shows you the differences between two versions of the page.

Link to this comparison view

Both sides previous revisionPrevious revision
Next revision
Previous revision
en-us_products:mp_studio:monitoring [2026/11/05 10:13] – external edit 127.0.0.1en-us_products:mp_studio:monitoring [2026/11/12 21:13] (current) – external edit 127.0.0.1
Line 1: Line 1:
 ====== MP STUDIO 2 Phase 7 · Monitoring and the Data Table ====== ====== MP STUDIO 2 Phase 7 · Monitoring and the Data Table ======
  
-Monitoring shows the state of the program running on the device on the MP STUDIO 2 screen in real time. You can check values on the ladder canvas, in the Data Table, on the Watch card and in the Value Trend graph, and change values on the device with value writes and forced I/O.+Monitoring shows the state of the program running on the PLC on the MP STUDIO 2 screen in real time. You can check values on the ladder canvas, in the Data Table, on the Watch card and in the Value trend graph, and change values on the PLC with value writes and forced I/O.
  
-{{ :en-us_products:mp_studio:monitor-flow.svg?1000 |Figure 1. What the PC and the device exchange during monitoring }}+{{ :en-us_products:mp_studio:monitor-flow.svg?1000 |Figure 1. What the PC and the PLC exchange during monitoring }}
  
 ===== Starting and Stopping Ladder Monitoring ===== ===== Starting and Stopping Ladder Monitoring =====
  
-  - Download the current project to the device.+  - Download the current project to the PLC.
   - Click **Monitoring** in the top band or press ''Ctrl+M'' (**Run → Monitoring**).   - Click **Monitoring** in the top band or press ''Ctrl+M'' (**Run → Monitoring**).
   - To stop monitoring, press ''Esc'' or ''Ctrl+M''.   - To stop monitoring, press ''Esc'' or ''Ctrl+M''.
Line 15: Line 15:
   * **① Power flow:** contacts, coils, wires and function blocks that carry power change to the power-flow color. A green frame is shown around the canvas while monitoring.   * **① Power flow:** contacts, coils, wires and function blocks that carry power change to the power-flow color. A green frame is shown around the canvas while monitoring.
   * **② Current values:** values of timer, counter and data addresses are shown above the cells.   * **② Current values:** values of timer, counter and data addresses are shown above the cells.
-  * **③ Device pill:** shows **Monitoring · port** and the scan time (SCAN). +  * **③ PLC status indicator:** shows **Monitoring · port** and the scan time (SCAN). 
-  * **④ Status pills:** show the scan time (**SCAN TIME**) and the firmware version of the device.+  * **④ Status indicators:** show the scan time (**SCAN TIME**) and the firmware version of the PLC.
  
 If you edit the ladder while monitoring, monitoring is turned off with the notice **Monitoring stopped because the program changed.** To check the edited program, download it again and then turn monitoring back on. If you edit the ladder while monitoring, monitoring is turned off with the notice **Monitoring stopped because the program changed.** To check the edited program, download it again and then turn monitoring back on.
  
-==== Device Program Differs ====+==== PLC Program Differs ====
  
-If you edit the ladder after downloading and then turn monitoring on, the device pill shows **Device program differs**. The device is still running the previous program, so a value on the screen may belong to a different cell. When you see this tag, download again.+If you edit the ladder after downloading and then turn monitoring on, the PLC status indicator shows **PLC program differs**. The PLC is still running the previous program, so a value on the screen may belong to a different cell. When you see this tag, download again.
  
-{{ :en-us_products:mp_studio:program-stale-pill.svg?700 |Figure 3. The Device program differs tag }}+{{ :en-us_products:mp_studio:program-stale-pill.svg?700 |Figure 3. The PLC program differs tag }}
  
 ==== No Response ==== ==== No Response ====
  
-If the device stops responding during monitoring, the device pill and the status pills show **No response**. Check the cable, the device power and the communication port settings.+If the PLC stops responding during monitoring, the PLC status indicator and the status indicators show **No response**. Check the cable, the PLC power and the communication port settings.
  
 ===== Write Value to Memory ===== ===== Write Value to Memory =====
Line 43: Line 43:
 ===== Force ON and Force OFF ===== ===== Force ON and Force OFF =====
  
-During monitoring, right-click a bit cell and use **Force ON** or **Force OFF** to force that point on or off. The **Force** buttons in the Inspector do the same. You can check and release all forced points at once in the [[#forced_input_and_output|FORCE INPUT / OUTPUT]] window.+During monitoring, right-click a bit cell and use **Force ON** or **Force OFF** to force that point on or off. The buttons next to the **Force** label in the Inspector do the same. You can check and release all forced points at once in the [[#forced_input_and_output|Force Input/Output]] window.
  
 {{ :en-us_products:mp_studio:monitor-context-menu.png?285 |Figure 5. The right-click menu of a cell during monitoring }} {{ :en-us_products:mp_studio:monitor-context-menu.png?285 |Figure 5. The right-click menu of a cell during monitoring }}
Line 57: Line 57:
   - Enter an address such as ''D10'', ''M0'' or ''R1'' in the **① Address** column and press ''Tab'' to move to the next cell. If the address has a symbol, it is shown in the **Symbol** column.   - Enter an address such as ''D10'', ''M0'' or ''R1'' in the **① Address** column and press ''Tab'' to move to the next cell. If the address has a symbol, it is shown in the **Symbol** column.
   - **② Format** shows the data type of the address (''BIT'', ''WORD'' and so on). For word values, choose the display format, such as signed decimal, in the drop-down next to **Value**.   - **② Format** shows the data type of the address (''BIT'', ''WORD'' and so on). For word values, choose the display format, such as signed decimal, in the drop-down next to **Value**.
-  - Click **③ Monitoring** to start reading values. While monitoring, the button changes to **Stop Monitoring**. +  - Click **③ Monitoring** to start reading values. While monitoring, the button changes to **Stop monitoring**. 
-  - To change a value, enter it in **④ Modify** and click **Force Write**. You can enter decimal, ''0x'' (hexadecimal) or ''0b'' (binary) values.+  - To change a value, enter it in **④ Value to write** and click **Force write**. You can enter decimal, ''0x'' (hexadecimal) or ''0b'' (binary) values.
  
   * Use **⑤ Save .dt** and **Open .dt** to save the address list to a file and load it again.   * Use **⑤ Save .dt** and **Open .dt** to save the address list to a file and load it again.
-  * Click **⑥ Trend** to open the [[#value_trend_graph|Value Trend]] panel.+  * Click **⑥ Trend** to open the [[#value_trend_graph|Value trend]] panel.
   * Click **✕** at the end of a row to delete that row, or **Clear** to delete all rows.   * Click **✕** at the end of a row to delete that row, or **Clear** to delete all rows.
   * The registered address list is remembered separately for each project file.   * The registered address list is remembered separately for each project file.
Line 79: Line 79:
 ==== Watch Card ==== ==== Watch Card ====
  
-The addresses and values registered in the Data Table are also shown on the **Watch** card in the right column. If monitoring is on, the values on the Watch card keep updating even after you close the Data Table window.+The addresses and values registered in the Data Table are also shown on the **Watch** card in the right column. If monitoring is on, the values on the Watch card keep updating even after you close the Data Table window. If the Watch card is not shown, select **View → Watch** or press ''Alt+4'' to turn it on.
  
 {{ :en-us_products:mp_studio:watch-card-live.png?480 |Figure 8. The Watch card during monitoring }} {{ :en-us_products:mp_studio:watch-card-live.png?480 |Figure 8. The Watch card during monitoring }}
Line 85: Line 85:
 ===== Value Trend Graph ===== ===== Value Trend Graph =====
  
-Click **Trend** in the Data Table to open the **Value Trend** panel, which shows how the values of the registered addresses change over time.+Click **Trend** in the Data Table to open the **Value trend** panel, which shows how the values of the registered addresses change over time.
  
-{{ :en-us_products:mp_studio:trend-panel-marked.svg?900 |Figure 9. The Value Trend panel }}+{{ :en-us_products:mp_studio:trend-panel-marked.svg?900 |Figure 9. The Value trend panel }}
  
-  * **① Start Recording and Stop Recording:** start or stop recording values. While recording, the number of recorded rows is shown.+  * **① Start recording and Stop recording:** start or stop recording values. While recording, the number of recorded rows is shown.
   * **② Pause and Resume:** freeze or resume only the graph display. Recording continues.   * **② Pause and Resume:** freeze or resume only the graph display. Recording continues.
   * **③ Time span:** choose the time range shown on the screen (seconds or minutes).   * **③ Time span:** choose the time range shown on the screen (seconds or minutes).
Line 101: Line 101:
 ===== Forced Input and Output ===== ===== Forced Input and Output =====
  
-Select **Run → FORCE INPUT / OUTPUT** to open the **FORCE INPUT / OUTPUT** window. Forced I/O makes an input point read a set value instead of its real signal, or makes an output point send a set value regardless of the ladder result.+Select **Run → Force Input/Output** to open the **Force Input/Output** window. Forced I/O makes an input point read a set value instead of its real signal, or makes an output point send a set value regardless of the ladder result.
  
-{{ :en-us_products:mp_studio:force-io-dialog-marked.svg?900 |Figure 10. The FORCE INPUT / OUTPUT window }}+{{ :en-us_products:mp_studio:force-io-dialog-marked.svg?900 |Figure 10. The Force Input/Output window }}
  
   - In **① the input points** and **② the output points**, choose ON or OFF for the points to force. Dimmed points do not exist on this model.   - In **① the input points** and **② the output points**, choose ON or OFF for the points to force. Dimmed points do not exist on this model.
-  - Click **③ Apply Force** to send them to the device. +  - Click **③ Apply force** to send them to the PLC. 
-  - Click **④ Read Status** to read the force state of the device again. The number of points forced ON and OFF is shown at the top of the window. +  - Click **④ Read status** to read the force state of the PLC again. The number of points forced ON and OFF is shown at the top of the window. 
-  - Read **⑤ the notice** for how Apply Force works and how to release forced points.+  - Read **⑤ the notice** for how Apply force works and how to release forced points.
  
-> **Caution:** Applied force values are stored in the device and stay in effect after a power cycle or a program re-download. To release them, press **Clear**, then **Apply Force**.+> **Caution:** Applied force values are stored in the PLC and stay in effect after a power cycle or a program re-download. To release them, click **Clear**, then **Apply force**.
  
-If both ON and OFF are set for one point, the device applies OFF. When points are forced, the device pill shows **Forced N** during monitoring; click it to open this window. Click **Show Frames** to see the communication frames that will be sent to the device.+If both ON and OFF are set for one point, the PLC applies OFF. When points are forced, the PLC status indicator shows **Forced N** during monitoring; click it to open this window. Click **Show frames** to see the communication frames that will be sent to the PLC.
  
 ===== Related Pages ===== ===== Related Pages =====
en-us_products/mp_studio/monitoring.1793841188.txt.gz · Last modified: by 127.0.0.1