en-us_products:mp_studio:screen_layout
Differences
This shows you the differences between two versions of the page.
| Next revision | Previous revision | ||
| en-us_products:mp_studio:screen_layout [2026/10/30 11:27] – created - external edit 127.0.0.1 | en-us_products:mp_studio:screen_layout [2026/11/12 20:37] (current) – external edit 127.0.0.1 | ||
|---|---|---|---|
| Line 1: | Line 1: | ||
| ====== MP STUDIO 2 Phase 2 · Screen Layout ====== | ====== MP STUDIO 2 Phase 2 · Screen Layout ====== | ||
| - | |||
| - | [[products: | ||
| MP STUDIO 2 puts the ladder canvas in the middle of the screen and arranges the tools and information panels around it. The panels sit in columns on the left and right so that they do not cover the ladder, and you can show only the panels you need. | MP STUDIO 2 puts the ladder canvas in the middle of the screen and arranges the tools and information panels around it. The panels sit in columns on the left and right so that they do not cover the ladder, and you can show only the panels you need. | ||
| Line 8: | Line 6: | ||
| ^ No. ^ Area ^ Role ^ | ^ No. ^ Area ^ Role ^ | ||
| - | | ① | Top band | File and tool buttons, document name, device pill, and the Simulate, Connect, Monitoring and Download buttons | | + | | ① | Top band | File and tool buttons, document name, PLC status indicator, and the Simulate, Connect, Monitoring and Download buttons | |
| | ② | Strip row | Menus, program tabs, command bar (find and zoom) and panel toggle buttons | | | ② | Strip row | Menus, program tabs, command bar (find and zoom) and panel toggle buttons | | ||
| - | | ③ | Symbol rail | Buttons for placing contacts, coils and wires ('' | + | | ③ | Symbol rail | Buttons for placing contacts, coils and wires ('' |
| - | | ④ | Functions panel | Function categories, search and the Mark (bookmark) list | | + | | ④ | Functions panel | Function categories, search and the bookmark list | |
| | ⑤ | Ladder canvas | Where you edit rungs and where monitoring values are shown | | | ⑤ | Ladder canvas | Where you edit rungs and where monitoring values are shown | | ||
| | ⑥ | Inspector | Address, symbol name, comment, current value and uses of the selected cell | | | ⑥ | Inspector | Address, symbol name, comment, current value and uses of the selected cell | | ||
| | ⑦ | Watch card | Values of the addresses registered in the Data Table | | | ⑦ | Watch card | Values of the addresses registered in the Data Table | | ||
| - | Depending on the situation, [[#status_pills|status | + | Depending on the situation, [[#status_indicators|status |
| ===== Top Band ===== | ===== Top Band ===== | ||
| - | {{ : | + | {{ : |
| * **① File buttons:** New, Open, Save, Save As | * **① File buttons:** New, Open, Save, Save As | ||
| - | * **② Document name:** the name of the '' | + | * **② Document name:** the name of the project file you are editing ('' |
| - | * **③ Device pill:** connection state, model, and the scan time (SCAN) while monitoring | + | * **③ PLC status indicator:** connection state, model, and the scan time (SCAN) while monitoring |
| - | * **④ Tool buttons:** Find& | + | * **④ Tool buttons:** Find & Replace, Used Data, Symbol |
| * **⑤ Run buttons:** Simulate, Connect (Ethernet connection), | * **⑤ Run buttons:** Simulate, Connect (Ethernet connection), | ||
| Hover over a button to see its name and shortcut. **Connect** is shown only when the download channel is '' | Hover over a button to see its name and shortcut. **Connect** is shown only when the download channel is '' | ||
| - | ==== Device Pill ==== | + | ==== PLC Status Indicator |
| - | The device pill shows the state of the connection to the device | + | The PLC status indicator |
| - | {{ : | + | {{ : |
| ^ Shown as ^ Meaning ^ | ^ Shown as ^ Meaning ^ | ||
| - | | Not connected | No device | + | | Not connected | No PLC is connected. | |
| | Blinking dot | Waiting for the Ethernet connection to be established. | | | Blinking dot | Waiting for the Ethernet connection to be established. | | ||
| - | | Ethernet connected · address | Connected to the device | + | | Ethernet connected · address | Connected to the PLC over Ethernet. | |
| - | | Monitoring · port · SCAN | Monitoring; the device | + | | Monitoring · port · SCAN | Monitoring; the PLC scan time is shown. | |
| | Monitoring · SIM | A simulation is running ([[: | | Monitoring · SIM | A simulation is running ([[: | ||
| | Monitoring (fixed areas only) | The program check did not pass, so only the fixed memory areas are being read. | | | Monitoring (fixed areas only) | The program check did not pass, so only the fixed memory areas are being read. | | ||
| - | | No response | The device | + | | No response | The PLC stopped responding during monitoring. | |
| - | | Forced N | N points are forced. Click it to open the FORCE INPUT / OUTPUT | + | | Forced N | N points are forced. Click it to open the Force Input/Output |
| - | | Device | + | | PLC program differs | The ladder was edited after the download. The PLC is still running the previous program. | |
| ===== Strip Row ===== | ===== Strip Row ===== | ||
| Line 51: | Line 49: | ||
| {{ : | {{ : | ||
| - | * **① Menus:** Project, Edit, View, Search, Run, Setting, Help | + | * **① Menus:** Project, Edit, View, Search, Run, Settings, Help |
| * **② Program tabs:** split the program into several tabs. Click **+** to add a tab. | * **② Program tabs:** split the program into several tabs. Click **+** to add a tab. | ||
| * **③ Command bar:** the address search box ('' | * **③ Command bar:** the address search box ('' | ||
| - | * **④ Panel toggle buttons:** show or hide the Symbol Rail, Functions, Inspector, Watch, Command Bar and Status | + | * **④ Panel toggle buttons:** show or hide the Symbol Rail, Functions, Inspector, Watch, Command Bar and Status |
| ==== Program Tabs ==== | ==== Program Tabs ==== | ||
| Line 63: | Line 61: | ||
| * Row numbers start from 0 on every tab. | * Row numbers start from 0 on every tab. | ||
| - | * The device | + | * The PLC receives a single program made of the tabs joined in order. |
| * Switch tabs with '' | * Switch tabs with '' | ||
| Line 70: | Line 68: | ||
| {{ : | {{ : | ||
| - | The symbol rail buttons do the same as the function keys, and each button shows its function key below the symbol. The **Functions** button at the bottom opens and closes | + | The symbol rail buttons do the same thing as the function keys, and each button shows its function key below the symbol. The **Functions** button at the bottom opens the **Insert Function** window (the same as '' |
| ===== Ladder Canvas ===== | ===== Ladder Canvas ===== | ||
| Line 93: | Line 91: | ||
| {{ : | {{ : | ||
| - | * **① Element and address:** the element type of the cell (NO, NC, Coil, Fn and so on), its address, and its row and column | + | * **① Element and address:** the element type of the cell (NO, NC, Coil, Fn and so on), its address, and its tab, row and column |
| - | * **② Address, Symbol | + | * **② Address, Symbol |
| * **③ Add to Watch:** adds this address to the Data Table and the Watch card. An address that is already registered is shown as **Watching**. | * **③ Add to Watch:** adds this address to the Data Table and the Watch card. An address that is already registered is shown as **Watching**. | ||
| * **④ Used at:** a list of the cells that use the same address. Click a line to go to that cell. | * **④ Used at:** a list of the cells that use the same address. Click a line to go to that cell. | ||
| - | During monitoring and simulation, the **Current value** is shown as well, and bit addresses get **Force** buttons (**ON** and **OFF**). If the cell has a problem, the reason is shown at the bottom of the Inspector. | + | During monitoring and simulation, the **Current value** is shown as well, and bit addresses get **ON** and **OFF** buttons next to the **Force** label. If the cell has a problem, the reason is shown at the bottom of the Inspector. |
| ===== Watch Card ===== | ===== Watch Card ===== | ||
| Line 108: | Line 106: | ||
| When there are no addresses to watch, **No addresses to watch** is shown. Click the **Data Table** button at the bottom right of the card to open the Data Table window. | When there are no addresses to watch, **No addresses to watch** is shown. Click the **Data Table** button at the bottom right of the card to open the Data Table window. | ||
| - | ===== Status | + | ===== Status |
| - | The status | + | The status |
| - | {{ : | + | {{ : |
| - | The connection state and model are also shown in the device pill in the top band. How to move between error and warning cells is described in [[: | + | The connection state and model are also shown in the PLC status indicator |
| ===== Showing and Hiding Panels ===== | ===== Showing and Hiding Panels ===== | ||
| Line 128: | Line 126: | ||
| | '' | | '' | ||
| | '' | | '' | ||
| - | | '' | + | | '' |
| | '' | | '' | ||
en-us_products/mp_studio/screen_layout.1793327273.txt.gz · Last modified: by 127.0.0.1