en-us_products:mp_studio:screen_layout
Differences
This shows you the differences between two versions of the page.
| Both sides previous revisionPrevious revisionNext revision | Previous revision | ||
| en-us_products:mp_studio:screen_layout [2026/11/05 10:13] – external edit 127.0.0.1 | en-us_products:mp_studio:screen_layout [2026/11/12 20:37] (current) – external edit 127.0.0.1 | ||
|---|---|---|---|
| Line 6: | Line 6: | ||
| ^ No. ^ Area ^ Role ^ | ^ No. ^ Area ^ Role ^ | ||
| - | | ① | Top band | File and tool buttons, document name, device pill, and the Simulate, Connect, Monitoring and Download buttons | | + | | ① | Top band | File and tool buttons, document name, PLC status indicator, and the Simulate, Connect, Monitoring and Download buttons | |
| | ② | Strip row | Menus, program tabs, command bar (find and zoom) and panel toggle buttons | | | ② | Strip row | Menus, program tabs, command bar (find and zoom) and panel toggle buttons | | ||
| - | | ③ | Symbol rail | Buttons for placing contacts, coils and wires ('' | + | | ③ | Symbol rail | Buttons for placing contacts, coils and wires ('' |
| - | | ④ | Functions panel | Function categories, search and the Mark (bookmark) list | | + | | ④ | Functions panel | Function categories, search and the bookmark list | |
| | ⑤ | Ladder canvas | Where you edit rungs and where monitoring values are shown | | | ⑤ | Ladder canvas | Where you edit rungs and where monitoring values are shown | | ||
| | ⑥ | Inspector | Address, symbol name, comment, current value and uses of the selected cell | | | ⑥ | Inspector | Address, symbol name, comment, current value and uses of the selected cell | | ||
| | ⑦ | Watch card | Values of the addresses registered in the Data Table | | | ⑦ | Watch card | Values of the addresses registered in the Data Table | | ||
| - | Depending on the situation, [[#status_pills|status | + | Depending on the situation, [[#status_indicators|status |
| ===== Top Band ===== | ===== Top Band ===== | ||
| - | {{ : | + | {{ : |
| * **① File buttons:** New, Open, Save, Save As | * **① File buttons:** New, Open, Save, Save As | ||
| - | * **② Document name:** the name of the '' | + | * **② Document name:** the name of the project file you are editing ('' |
| - | * **③ Device pill:** connection state, model, and the scan time (SCAN) while monitoring | + | * **③ PLC status indicator:** connection state, model, and the scan time (SCAN) while monitoring |
| - | * **④ Tool buttons:** Find& | + | * **④ Tool buttons:** Find & Replace, Used Data, Symbol |
| * **⑤ Run buttons:** Simulate, Connect (Ethernet connection), | * **⑤ Run buttons:** Simulate, Connect (Ethernet connection), | ||
| Hover over a button to see its name and shortcut. **Connect** is shown only when the download channel is '' | Hover over a button to see its name and shortcut. **Connect** is shown only when the download channel is '' | ||
| - | ==== Device Pill ==== | + | ==== PLC Status Indicator |
| - | The device pill shows the state of the connection to the device | + | The PLC status indicator |
| - | {{ : | + | {{ : |
| ^ Shown as ^ Meaning ^ | ^ Shown as ^ Meaning ^ | ||
| - | | Not connected | No device | + | | Not connected | No PLC is connected. | |
| | Blinking dot | Waiting for the Ethernet connection to be established. | | | Blinking dot | Waiting for the Ethernet connection to be established. | | ||
| - | | Ethernet connected · address | Connected to the device | + | | Ethernet connected · address | Connected to the PLC over Ethernet. | |
| - | | Monitoring · port · SCAN | Monitoring; the device | + | | Monitoring · port · SCAN | Monitoring; the PLC scan time is shown. | |
| | Monitoring · SIM | A simulation is running ([[: | | Monitoring · SIM | A simulation is running ([[: | ||
| | Monitoring (fixed areas only) | The program check did not pass, so only the fixed memory areas are being read. | | | Monitoring (fixed areas only) | The program check did not pass, so only the fixed memory areas are being read. | | ||
| - | | No response | The device | + | | No response | The PLC stopped responding during monitoring. | |
| - | | Forced N | N points are forced. Click it to open the FORCE INPUT / OUTPUT | + | | Forced N | N points are forced. Click it to open the Force Input/Output |
| - | | Device | + | | PLC program differs | The ladder was edited after the download. The PLC is still running the previous program. | |
| ===== Strip Row ===== | ===== Strip Row ===== | ||
| Line 49: | Line 49: | ||
| {{ : | {{ : | ||
| - | * **① Menus:** Project, Edit, View, Search, Run, Setting, Help | + | * **① Menus:** Project, Edit, View, Search, Run, Settings, Help |
| * **② Program tabs:** split the program into several tabs. Click **+** to add a tab. | * **② Program tabs:** split the program into several tabs. Click **+** to add a tab. | ||
| * **③ Command bar:** the address search box ('' | * **③ Command bar:** the address search box ('' | ||
| - | * **④ Panel toggle buttons:** show or hide the Symbol Rail, Functions, Inspector, Watch, Command Bar and Status | + | * **④ Panel toggle buttons:** show or hide the Symbol Rail, Functions, Inspector, Watch, Command Bar and Status |
| ==== Program Tabs ==== | ==== Program Tabs ==== | ||
| Line 61: | Line 61: | ||
| * Row numbers start from 0 on every tab. | * Row numbers start from 0 on every tab. | ||
| - | * The device | + | * The PLC receives a single program made of the tabs joined in order. |
| * Switch tabs with '' | * Switch tabs with '' | ||
| Line 68: | Line 68: | ||
| {{ : | {{ : | ||
| - | The symbol rail buttons do the same as the function keys, and each button shows its function key below the symbol. The **Functions** button at the bottom opens and closes | + | The symbol rail buttons do the same thing as the function keys, and each button shows its function key below the symbol. The **Functions** button at the bottom opens the **Insert Function** window (the same as '' |
| ===== Ladder Canvas ===== | ===== Ladder Canvas ===== | ||
| Line 91: | Line 91: | ||
| {{ : | {{ : | ||
| - | * **① Element and address:** the element type of the cell (NO, NC, Coil, Fn and so on), its address, and its row and column | + | * **① Element and address:** the element type of the cell (NO, NC, Coil, Fn and so on), its address, and its tab, row and column |
| - | * **② Address, Symbol | + | * **② Address, Symbol |
| * **③ Add to Watch:** adds this address to the Data Table and the Watch card. An address that is already registered is shown as **Watching**. | * **③ Add to Watch:** adds this address to the Data Table and the Watch card. An address that is already registered is shown as **Watching**. | ||
| * **④ Used at:** a list of the cells that use the same address. Click a line to go to that cell. | * **④ Used at:** a list of the cells that use the same address. Click a line to go to that cell. | ||
| - | During monitoring and simulation, the **Current value** is shown as well, and bit addresses get **Force** buttons (**ON** and **OFF**). If the cell has a problem, the reason is shown at the bottom of the Inspector. | + | During monitoring and simulation, the **Current value** is shown as well, and bit addresses get **ON** and **OFF** buttons next to the **Force** label. If the cell has a problem, the reason is shown at the bottom of the Inspector. |
| ===== Watch Card ===== | ===== Watch Card ===== | ||
| Line 106: | Line 106: | ||
| When there are no addresses to watch, **No addresses to watch** is shown. Click the **Data Table** button at the bottom right of the card to open the Data Table window. | When there are no addresses to watch, **No addresses to watch** is shown. Click the **Data Table** button at the bottom right of the card to open the Data Table window. | ||
| - | ===== Status | + | ===== Status |
| - | The status | + | The status |
| - | {{ : | + | {{ : |
| - | The connection state and model are also shown in the device pill in the top band. How to move between error and warning cells is described in [[: | + | The connection state and model are also shown in the PLC status indicator |
| ===== Showing and Hiding Panels ===== | ===== Showing and Hiding Panels ===== | ||
| Line 126: | Line 126: | ||
| | '' | | '' | ||
| | '' | | '' | ||
| - | | '' | + | | '' |
| | '' | | '' | ||
en-us_products/mp_studio/screen_layout.1793841188.txt.gz · Last modified: by 127.0.0.1