| ====== MP STUDIO 2 Phase 8 · Simulation ====== | ====== MP STUDIO 2 Phase 8 · Simulation ====== | ||
| - | Simulation runs the ladder on a virtual | + | Simulation runs the ladder on a virtual |
| {{ : | {{ : | ||
| - | **① The simulation bar**, **② a purple dashed frame** and **③ the current values in the Inspector** are shown. The device pill shows **Monitoring · SIM**. | + | **① The simulation bar**, **② a purple dashed frame** and **③ the current values in the Inspector** are shown. The PLC status indicator |
| ===== Starting and Stopping ===== | ===== Starting and Stopping ===== | ||
| Line 13: | Line 13: | ||
| - To stop, click **Stop simulation** at the right end of the bar, or click **Simulate** again. | - To stop, click **Stop simulation** at the right end of the bar, or click **Simulate** again. | ||
| - | Simulation and device | + | Simulation and PLC monitoring cannot run at the same time. Turning on simulation while monitoring turns monitoring off. |
| ===== Simulation Bar ===== | ===== Simulation Bar ===== | ||
| Line 19: | Line 19: | ||
| {{ : | {{ : | ||
| - | * **① State:** shows **Running**, | + | * **① State:** shows **Running**, |
| * **② Pause and Resume:** pauses or resumes scanning. | * **② Pause and Resume:** pauses or resumes scanning. | ||
| * **③ Step one scan:** runs a single scan while paused. | * **③ Step one scan:** runs a single scan while paused. | ||
| Line 27: | Line 27: | ||
| * **⑦ Stop simulation** | * **⑦ Stop simulation** | ||
| - | If the program has such cells, | + | If the program has such cells, |
| ===== Changing Inputs ===== | ===== Changing Inputs ===== | ||
| Line 36: | Line 36: | ||
| {{ : | {{ : | ||
| - | In Figure 3, **① the P0 chip** | + | In Figure 3, **① the P0 chip** |
| ===== Virtual Sensors ===== | ===== Virtual Sensors ===== | ||
| - | Function cells that read signals from outside the device, such as '' | + | Function cells that read signals from outside the PLC, such as '' |
| {{ : | {{ : | ||
| Line 48: | Line 48: | ||
| ===== What Simulation Cannot Check ===== | ===== What Simulation Cannot Check ===== | ||
| - | The simulator calculates the behavior of the device | + | The simulator calculates the behavior of the PLC on your PC. Check the following on the real PLC: |
| - | * The actual responses of serial communication (Modbus, CNET, IBUS and so on) and external devices (I2C, LCD, RTC and so on) | + | * The actual responses of serial communication (Modbus, CNET, IBUS and so on) and external devices (I2C, LCD, RTC and so on). Devices registered in the Modbus RTU master' |
| * The actual I/O wiring and scan time | * The actual I/O wiring and scan time | ||
| * Cells the simulator cannot run (shown with diagonal hatching). Those rows are skipped and the rest is run. | * Cells the simulator cannot run (shown with diagonal hatching). Those rows are skipped and the rest is run. | ||