en-us_products:mpino_studio2:menus_settings
Differences
This shows you the differences between two versions of the page.
| Both sides previous revisionPrevious revisionNext revision | Previous revision | ||
| en-us_products:mpino_studio2:menus_settings [2026/11/13 00:27] – external edit 127.0.0.1 | en-us_products:mpino_studio2:menus_settings [2026/11/17 17:59] (current) – external edit 127.0.0.1 | ||
|---|---|---|---|
| Line 210: | Line 210: | ||
| ^ Marker ^ Item ^ Setting ^ | ^ Marker ^ Item ^ Setting ^ | ||
| | **①** | Channel | '' | | **①** | Channel | '' | ||
| - | | **②** | Protocol | None, Modbus RTU Slave, LS Electric Cnet Slave, MPLINK Master, | + | | **②** | Protocol | None, Modbus RTU Slave, LS Electric Cnet Slave, MPLINK Master, MPLINK Slave, or Modbus RTU Master |
| | **③** | Slave ID | 1–247 | | | **③** | Slave ID | 1–247 | | ||
| | **④** | Baud Rate | Baud used by the channel | | | **④** | Baud Rate | Baud used by the channel | | ||
| Line 219: | Line 219: | ||
| Select **None** to leave the channel unused. Selecting **Modbus RTU Slave** or **LS Electric Cnet Slave** enables the Slave ID and serial settings. The defaults are Slave ID 1, 115200bps, 8 data bits, 1 stop bit, and no parity. | Select **None** to leave the channel unused. Selecting **Modbus RTU Slave** or **LS Electric Cnet Slave** enables the Slave ID and serial settings. The defaults are Slave ID 1, 115200bps, 8 data bits, 1 stop bit, and no parity. | ||
| - | **Modbus RTU Master** and **Modbus TCP/ | + | **Modbus TCP/ |
| Changes immediately update the current project and are used by the next build and upload. The current in-memory settings can be built before saving, but press '' | Changes immediately update the current project and are used by the next build and upload. The current in-memory settings can be built before saving, but press '' | ||
| Line 228: | Line 228: | ||
| **Modbus RTU Slave** and **LS Electric Cnet Slave** channels do not stop the ladder scan or other communication channels while they receive a request or send a response. | **Modbus RTU Slave** and **LS Electric Cnet Slave** channels do not stop the ladder scan or other communication channels while they receive a request or send a response. | ||
| + | |||
| + | A **Comm trace** row appears under each channel that has a protocol selected. See [[en-us_products: | ||
| ==== Modbus RTU Slave and LS Electric Cnet Slave Addresses ==== | ==== Modbus RTU Slave and LS Electric Cnet Slave Addresses ==== | ||
| Line 261: | Line 263: | ||
| For both protocols, timer current values are counts of the timer unit, not times. To convert a value to time, multiply it by the timer unit described in [[en-us_products: | For both protocols, timer current values are counts of the timer unit, not times. To convert a value to time, multiply it by the timer unit described in [[en-us_products: | ||
| + | |||
| + | For worked Modbus examples and a test from a PC, see [[: | ||
| ==== Memory Write List ==== | ==== Memory Write List ==== | ||
| Line 334: | Line 338: | ||
| | **⑤** | Used Memory | '' | | **⑤** | Used Memory | '' | ||
| | **⑥** | EEPROM Retain | '' | | **⑥** | EEPROM Retain | '' | ||
| - | | **⑦** | CLCD Settings | + | | **⑦** | CLCD Screen Editor |
| | **⑧** | RTC (Clock) Settings | - | Current project | Set up loading the time of an external clock module into D memory. | | | **⑧** | RTC (Clock) Settings | - | Current project | Set up loading the time of an external clock module into D memory. | | ||
| - | See [[en-us_products: | + | See [[en-us_products: |
| ==== Change Board ==== | ==== Change Board ==== | ||
| Line 446: | Line 450: | ||
| Option 2 does not automatically check whether the power-detect pin is used elsewhere. Select a pin that is not used for another I/O purpose. | Option 2 does not automatically check whether the power-detect pin is used elsewhere. Select a pin that is not used for another I/O purpose. | ||
| - | ==== CLCD Settings | + | ==== CLCD Screen Editor |
| - | Use **Settings → CLCD Settings** to create the screens shown on a character LCD connected to the board' | + | Use **Settings → CLCD Screen Editor** to create the screens shown on a character LCD connected to the board' |
| Supported LCDs are HD44780-compatible character LCDs fitted with a PCF8574 I²C adapter module. Choose a size of 20×4 or 16×2. A project can use up to 4 LCDs, and each LCD can have up to 255 screens. | Supported LCDs are HD44780-compatible character LCDs fitted with a PCF8574 I²C adapter module. Choose a size of 20×4 or 16×2. A project can use up to 4 LCDs, and each LCD can have up to 255 screens. | ||
| - | {{ : | + | {{ : |
| ^ Marker ^ Screen area ^ Action ^ | ^ Marker ^ Screen area ^ Action ^ | ||
| Line 491: | Line 495: | ||
| You can also select a range by dragging with the mouse. A value field inserted without a range is 6 cells wide for Integer and Real and 4 cells wide for Hex and Bit. Drag a value field to move it, or drag the right edge of the selected field to change its width. A field cannot be placed where it overlaps another field or extends past the screen. | You can also select a range by dragging with the mouse. A value field inserted without a range is 6 cells wide for Integer and Real and 4 cells wide for Hex and Bit. Drag a value field to move it, or drag the right edge of the selected field to change its width. A field cannot be placed where it overlaps another field or extends past the screen. | ||
| - | Undo in this window is recorded separately from ladder undo, and the undo history is cleared when the window closes. CLCD settings | + | Undo in this window is recorded separately from ladder undo, and the undo history is cleared when the window closes. |
| Use the **Field** tab to set the memory address and display format of the selected value field. | Use the **Field** tab to set the memory address and display format of the selected value field. | ||
| Line 547: | Line 551: | ||
| When the condition turns OFF, the LCD keeps the last screen and its value fields keep updating. If PAGE is not a screen number of that LCD, the screen does not change. An LCD whose '' | When the condition turns OFF, the LCD keeps the last screen and its value fields keep updating. If PAGE is not a screen number of that LCD, the screen does not change. An LCD whose '' | ||
| - | Right-click a '' | + | Right-click a '' |
| - | If you confirm a '' | + | If you confirm a '' |
| See [[en-us_products: | See [[en-us_products: | ||
| - | The check results at the bottom of the window list errors and warnings in CLCD Settings | + | The check results at the bottom of the window list errors and warnings in the CLCD Screen Editor |
| **CLCD RAM** is an estimate of the board RAM used by the CLCD feature. It turns yellow when it exceeds 25% of the board RAM, and the build makes the final call on whether it fits. | **CLCD RAM** is an estimate of the board RAM used by the CLCD feature. It turns yellow when it exceeds 25% of the board RAM, and the build makes the final call on whether it fits. | ||
| Line 683: | Line 687: | ||
| | Pin addresses are incorrect after a board change. | Current board and Ladder Pin Map Settings | Check the addresses in **Settings → Ladder Pin Map Settings** and rebuild. | | | Pin addresses are incorrect after a board change. | Current board and Ladder Pin Map Settings | Check the addresses in **Settings → Ladder Pin Map Settings** and rebuild. | | ||
| | EEPROM Retain cannot be saved. | Memory range, overlap, capacity, and Power detect pin | Correct the indicated fields and select a power-detect pin for Option 2. | | | EEPROM Retain cannot be saved. | Memory range, overlap, capacity, and Power detect pin | Correct the indicated fields and select a power-detect pin for Option 2. | | ||
| - | | Nothing appears on the LCD. | '' | + | | Nothing appears on the LCD. | '' |
| | Update checking fails. | Internet and update-server connection | Check the network connection and try again. | | | Update checking fails. | Internet and update-server connection | Check the network connection and try again. | | ||
en-us_products/mpino_studio2/menus_settings.1794497224.txt.gz · Last modified: by 127.0.0.1