Skip to content
MPA-64A64T industrial PLC controller — front view

MPA Series

MPA-64A64T

MPA-64A64T Industrial PLC Controller

I/O at a glance
64 DI / 64 Transistor / RS-232 / RS-485 / UART / I²C

MPA-64A64T is an industrial PLC controller with 64 isolated digital inputs and 64 transistor (sink) outputs. Onboard RS-232, RS-485, UART, I²C, programmed in MP STUDIO ladder logic. DIN-rail mountable for automation, testing, HMI integration and machine control.

$471.00 In stock
Options
Analogue input module (X)

Adding an expansion module means the unit is dismantled and re-assembled to order, so such an order is difficult to exchange or refund. Some combinations are not available on some models; if yours cannot be built we will contact you.

PT100Ω temperature input module (F)
Analogue output module (Y)
Pulse output module (K)
Add-on products
Add related items you may need (optional)
Super capacitor DDL 5.5V 1F — a radial supercapacitor with two leads, for the +5V terminal
Super Capacitor DDL 5.5V 1F
Super Capacitor DDL 5.5V 1F (power-fail retention)
$5.00
Total$471.00
Shipping

International shipping (EMS · DHL · UPS) — calculated at checkout by destination & weight

Dispatch

Ships the next business day (regardless of order time)

Large orders may take 1 extra day to dispatch

Returns & Exchange

Cancel before dispatch · request a return/exchange after delivery

Overview

/ OVERVIEW

MPA-64A64T is an industrial PLC controller with 64 isolated digital inputs and 64 transistor (sink) outputs. Onboard RS-232, RS-485, UART, I²C, programmed in MP STUDIO ladder logic. DIN-rail mountable for automation, testing, HMI integration and machine control.

Key features

  • Programmed in MP STUDIO ladder logic
  • 64 opto-isolated digital inputs, NPN/PNP selectable
  • 64 transistor (sink) outputs for fast DC switching
  • Industrial communication: RS-485, RS-232, UART, I²C · Modbus RTU
  • DIN-rail 35 mm mountable, isolated field I/O for the factory floor

Specifications

/ SPEC
Power inputDC 12V – 24V
Digital inputs64
Transistor outputs64
RS-2321ch
RS-4851ch
UART1ch
I²C1ch
Modbus RTUYes
LS CnetYes

Software

MP STUDIO — Ladder Logic

The MPS series is programmed in MP STUDIO, a free ladder-logic IDE. Draw the control logic as a ladder diagram and call analog, temperature, high-speed counter and pulse output straight from function blocks.

0000P0P320001@ONADCCHANNEL0MAX VALUE1000MIN VALUE0OUTD0
MP STUDIO ladder program example (from the user manual)

Ladder logic only

Contacts and coils — existing PLC experience transfers directly

Function blocks

ADC · NTEMP · HCNT · ENCODER · PWM, each a single block

Live monitoring

Ctrl+T to download, Ctrl+M to monitor and debug on the machine

Before the first download

Install MP STUDIO from the ILOGICS download centre, pick your model in the device list, set the COM port, and you can download straight away.

This model connects to the PC with an ordinary USB cable — no MP download cable is required, and the driver is Silicon Labs CP210x.

Power · Data retentionPower · Backup

DC 12V ~ 24V in, 5 V out — and your data survives the blackout

The controller takes DC 12V ~ 24V and an on-board regulator converts it to 5 V for the internal circuit. Size the supply for at least 24V 0.5A.

  • DC 12V ~ 24V

    Size the supply for 24V 0.5A or more

  • 5 V internal

    On-board regulator conversion

  • +5 V out

    From the I²C terminal block — limit not published

  • Supercapacitor hold-up

    Holds the +5 V rail up through a power cut

Before wiring the supply

  • An EEPROM section written about 100,000 times can fail, and a failed section reads back a random value after a power cut. For values that change constantly, use the supercapacitor method below.
  • USB power is for development and bench testing. With every output on, the board draws roughly 5 V 1 A — more than a PC port is meant to give — so the manual asks you to use a powered USB hub, or the external supply, once outputs are wired.
  • Do not exceed the stated input voltage range.
  • Do not reverse the supply polarity or mis-wire the input.

Where the power goes

DC 12V ~ 24V24V 0.5A min.REGULATORDC-DC to 5V5V internalFeeds the control circuit+5V terminalon the I²C blockUSB 5VDownload portSupercapacitorHolds the rail up
Supply input5 V railData retention

* Either source runs the controller: the external supply through the regulator, or the download port's 5 V directly. The supercapacitor sits on the same 5 V node and keeps it alive when both go away.

Power and data retention

Input voltageDC 12V ~ 24V
SMPS requirement24V 0.5A or more
Internal conversionOn-board regulator to 5 V
+5 V outputFrom the +5 V pole of the I²C terminal block — this model's manual states no current limit
USB-powered operationRuns on the PC's 5 V through the download port
Non-volatile memoryEEPROM, about 100,000 writes per section
Hold-up on a power cutSupercapacitor on the +5 V pole
Blackouts retainedMore than 100,000, writing only when the mains drops

Size the supply for 24V 0.5A or more, plus whatever the +5 V pole is feeding.

Keeping data through a blackout

Which method you want depends on how often the value changes. The first is a setting; the second needs one part and a few rungs.

EEPROM retentive area — values that change occasionally

Mark a retentive area under Settings → Data Memory in MP STUDIO and the runtime copies that memory into non-volatile EEPROM every time its value changes — no code to write. Because a section survives only about 100,000 writes, it belongs to setpoints, calibration data and machine configuration rather than to anything the scan updates.

Supercapacitor — values that change constantly

Fit a supercapacitor to the +5 V pole and the internal 5 V stays up for a moment after the main supply is cut. Wire the main supply into a digital input as well, add a rung that moves the live value into the retentive memory as soon as that input goes off, and a second rung that moves it back once on restart. The EEPROM is then written only at the instant of a blackout, so it survives more than 100,000 of them.

Downloads

/ FILES

FAQ

How many I/O points does the MPA-64A64T have?

The MPA-64A64T provides 64 isolated digital inputs and 64 transistor outputs, with onboard RS-485, RS-232, UART, I²C communication. See the specification table for the full breakdown.

Does the MPA-64A64T support Modbus RTU?

Yes. The MPA-64A64T supports Modbus RTU — master and slave alike — over its serial interface.

Related controllers

/ RELATED