User Tools

Site Tools


en-us_products:mpa_48a48r

Differences

This shows you the differences between two versions of the page.

Link to this comparison view

Next revision
Previous revision
en-us_products:mpa_48a48r [2026/09/07 21:52] – 만듦 - 바깥 편집 127.0.0.1en-us_products:mpa_48a48r [2026/10/25 08:42] (current) – external edit 127.0.0.1
Line 1: Line 1:
 ====== MPA-48A48R ====== ====== MPA-48A48R ======
  
-MPA Series is an assembled industrial PLC combining a CPU module with digital input and output modules. \\+The MPA Series comprises modular industrial PLCs assembled from a CPU module and digital input and output modules. \\
 Analog input/output, temperature sensor input, and high-speed pulse output modules can be added as options. \\ Analog input/output, temperature sensor input, and high-speed pulse output modules can be added as options. \\
 The selected I/O and optional modules are assembled and shipped as one product. Users cannot add or remove modules. The selected I/O and optional modules are assembled and shipped as one product. Users cannot add or remove modules.
Line 23: Line 23:
 |  Power  |  -  |  Supply voltage  | DC 12~24V \\ For DC 24V, a power supply rated 0.5A or more is recommended  | |  Power  |  -  |  Supply voltage  | DC 12~24V \\ For DC 24V, a power supply rated 0.5A or more is recommended  |
 |  Digital inputs  |  48 points \\ (Isolated)  |  Module 0: P0~P7 \\ Module 1: P8~P15 \\ Module 2: P16~P23 \\ Module 3: P24~P31 \\ Module 4: P32~P39 \\ Module 5: P40~P47  | Operating input voltage DC 0~80V \\ HIGH detection: DC 5V or higher \\ Optocoupler isolation  | |  Digital inputs  |  48 points \\ (Isolated)  |  Module 0: P0~P7 \\ Module 1: P8~P15 \\ Module 2: P16~P23 \\ Module 3: P24~P31 \\ Module 4: P32~P39 \\ Module 5: P40~P47  | Operating input voltage DC 0~80V \\ HIGH detection: DC 5V or higher \\ Optocoupler isolation  |
-|  Relay outputs  |  48 points \\ (Isolated dry contacts)  |  Module 0: P64~P71 \\ Module 1: P72~P79 \\ Module 2: P80~P87 \\ Module 3: P88~P95 \\ Module 4: P96~P103 \\ Module 5: P104~P111  | DC 0~30V or AC 0~250V \\ Max. 5A/1 points, 8A/1COM  |+|  Relay outputs  |  48 points \\ (Isolated dry contacts)  |  Module 0: P64~P71 \\ Module 1: P72~P79 \\ Module 2: P80~P87 \\ Module 3: P88~P95 \\ Module 4: P96~P103 \\ Module 5: P104~P111  | DC 0~30V or AC 0~250V \\ Max. 5A/1 point, 8A/1COM  |
 |  Optional modules  |  up to 20 points  |  Analog inputs \\ PT100Ω temperature sensor input  | Optional specifications  | |  Optional modules  |  up to 20 points  |  Analog inputs \\ PT100Ω temperature sensor input  | Optional specifications  |
 | ::: |  up to 12 points  |  Analog outputs \\ High-speed pulse outputs  | Optional specifications  | | ::: |  up to 12 points  |  Analog outputs \\ High-speed pulse outputs  | Optional specifications  |
Line 31: Line 31:
 ===== Digital inputs ===== ===== Digital inputs =====
  
 +[[:en-us_guide:wiring#digital_input_one_channel_check|See the one-channel digital-input check before wiring for the first time. →]]
 ^ Module ^ Group ^ Input contacts ^ Input configuration ^ Terminal blocks and wiring examples ^ ^ Module ^ Group ^ Input contacts ^ Input configuration ^ Terminal blocks and wiring examples ^
 | Module 0 | COM0 \\ COM1 | P0~P3 \\ P4~P7 | 8 isolated digital inputs \\ 4 points/1COM |  {{:en-us_products:mpa-input-8-wiring.svg?740|MPA-48A48R digital input wiring example}}  | | Module 0 | COM0 \\ COM1 | P0~P3 \\ P4~P7 | 8 isolated digital inputs \\ 4 points/1COM |  {{:en-us_products:mpa-input-8-wiring.svg?740|MPA-48A48R digital input wiring example}}  |
Line 45: Line 46:
 ===== Relay outputs ===== ===== Relay outputs =====
  
 +[[:en-us_guide:wiring#relay_output_one_channel_check|See the one-channel relay-output check before wiring for the first time. →]]
 ^ Module ^ Group ^ Output contacts ^ Contact configuration ^ Terminal blocks and wiring examples ^ ^ Module ^ Group ^ Output contacts ^ Contact configuration ^ Terminal blocks and wiring examples ^
 | Module 0 | COM0 \\ COM1 | P64~P67 \\ P68~P71 | 8 relay outputs \\ 4 points/1COM |  {{:en-us_products:mpa-relay-8-p64-wiring.svg?740|MPA-48A48R relay output wiring example}}  | | Module 0 | COM0 \\ COM1 | P64~P67 \\ P68~P71 | 8 relay outputs \\ 4 points/1COM |  {{:en-us_products:mpa-relay-8-p64-wiring.svg?740|MPA-48A48R relay output wiring example}}  |
Line 102: Line 104:
 ^ Rear view ^  ^ ^ Rear view ^  ^
 |  [[https://www.ilogics.net/docs/_media/products:mpa-48a48r-dimension-rear.svg|{{ :en-us_products:mpa-48a48r-dimension-rear.svg?nolink&420 }}]]  |  | |  [[https://www.ilogics.net/docs/_media/products:mpa-48a48r-dimension-rear.svg|{{ :en-us_products:mpa-48a48r-dimension-rear.svg?nolink&420 }}]]  |  |
 +
 +[[https://www.ilogics.net/en-us/products/mpa-48a48r|View MPA-48A48R price and purchase options]]
  
 [[:en-us_products:mpa|← Back to MPA Series comparison]] [[:en-us_products:mpa|← Back to MPA Series comparison]]
  
en-us_products/mpa_48a48r.1788785570.txt.gz · Last modified: by 127.0.0.1

Donate Powered by PHP Valid HTML5 Valid CSS Driven by DokuWiki