User Tools

Site Tools


en-us_products:mps_16a8r

Differences

This shows you the differences between two versions of the page.

Link to this comparison view

Both sides previous revisionPrevious revision
en-us_products:mps_16a8r [2026/09/17 12:16] – external edit 127.0.0.1en-us_products:mps_16a8r [2026/10/25 08:42] (current) – external edit 127.0.0.1
Line 1: Line 1:
 ====== MPS-16A8R ====== ====== MPS-16A8R ======
  
-MPS-16A8R is a all-in-one industrial PLC with 16 digital inputs and 8 relay outputs. Provides 4 analog inputs, 1 encoder/high-speed counter channel shared with I²C, and 3 serial communication channels.+MPS-16A8R is an all-in-one industrial PLC with 16 digital inputs and 8 relay outputs. It provides 4 analog inputs, 1 encoder/high-speed counter channel shared with I²C, and 3 serial communication channels.
  
 Program with ladder logic using MP STUDIO. Program with ladder logic using MP STUDIO.
Line 13: Line 13:
 |  Power  |  -  |  +5V, +12V, GND  | DC 9~12V (1A or more when using DC 12V) \\ +5V output: up to 100mA  | |  Power  |  -  |  +5V, +12V, GND  | DC 9~12V (1A or more when using DC 12V) \\ +5V output: up to 100mA  |
 |  Digital inputs  |  16 points \\ (Solid-state, isolated)  |  P0~P15  | DC 0~40V; HIGH detection at DC 5V or higher \\ COM0: P0~P7, COM1: P8~P15 \\ NPN/PNP input support  | |  Digital inputs  |  16 points \\ (Solid-state, isolated)  |  P0~P15  | DC 0~40V; HIGH detection at DC 5V or higher \\ COM0: P0~P7, COM1: P8~P15 \\ NPN/PNP input support  |
-|  Relay outputs  |  8 points \\ (Mechanical contacts, isolated)  |  P32~P39  | AC 250V or DC 30V \\ Max. 5A/1 points, 15A/1COM \\ 4 points/1COM  | +|  Relay outputs  |  8 points \\ (Mechanical contacts, isolated)  |  P32~P39  | AC 250V or DC 30V \\ Max. 5A/1 point, 15A/1COM \\ 4 points/1COM  | 
-|  Analog inputs  |  4 points \\ (Non-isolated)  |  AI0~AI3  | Factory default: DC 0~5V \\ 10bit \\ Input range or NTC option can be changed when ordering  |+|  Analog inputs  |  4 points \\ (Non-isolated)  |  AI0~AI3  | Factory default: DC 0~5V \\ 10-bit \\ Input range or NTC option can be changed when ordering  |
 |  High-Speed Counter / Encoder  |  1 channel \\ (Non-isolated)  |  SDA(A), SCL(B)  | DC 5V, Max. 50kHz \\ Shared with I²C  | |  High-Speed Counter / Encoder  |  1 channel \\ (Non-isolated)  |  SDA(A), SCL(B)  | DC 5V, Max. 50kHz \\ Shared with I²C  |
 |  Pulse outputs  |  0 points  |  -  | Not supported  | |  Pulse outputs  |  0 points  |  -  | Not supported  |
en-us_products/mps_16a8r.1789615018.txt.gz · Last modified: by 127.0.0.1