User Tools

Site Tools


en-us_products:mps_16a8r

MPS-16A8R

MPS-16A8R is a all-in-one industrial PLC with 16 digital inputs and 8 relay outputs. Provides 4 analog inputs, 1 encoder/high-speed counter channel shared with I²C, and 3 serial communication channels.

Program with ladder logic using MP STUDIO.

MPS-16A8R connector guide

Product Specifications

Category Quantity Terminal / Item Specifications
Programming method - - MP STUDIO
MP STUDIO2
(Ladder logic program)
Power - +5V, +12V, GND DC 9~12V (1A or more when using DC 12V)
+5V output: up to 100mA
Digital inputs 16 points
(Solid-state, isolated)
P0~P15 DC 0~40V; HIGH detection at DC 5V or higher
COM0: P0~P7, COM1: P8~P15
NPN/PNP input support
Relay outputs 8 points
(Mechanical contacts, isolated)
P32~P39 AC 250V or DC 30V
Max. 5A/1 points, 15A/1COM
4 points/1COM
Analog inputs 4 points
(Non-isolated)
AI0~AI3 Factory default: DC 0~5V
10bit
Input range or NTC option can be changed when ordering
High-Speed Counter / Encoder 1 channel
(Non-isolated)
SDA(A), SCL(B) DC 5V, Max. 50kHz
Shared with I²C
Pulse outputs 0 points - Not supported
Communication Channels 1 channel
(Non-isolated)
I²C I²C Master
Communication Channels 1 channel each
(Non-isolated)
RS-232, RS-485, UART Modbus RTU Slave
LS Industrial Systems Cnet(XGK) Slave
User-defined protocol
Memory - Flash 256KB (32KB used by system)
Data Memory 8KB (1KB used by system)

Digital inputs

See the one-channel digital-input check before wiring for the first time. →

Contact COM Input type Connector / Wiring example
P0~P7 COM0 NPN/PNP inputs MPS-16A8R digital-input
P8~P15 COM1 NPN/PNP inputs

Relay outputs

See the one-channel relay-output check before wiring for the first time. →

COM Contact Contact ratings Connector / Wiring example
COM2 P32~P35 AC 250V or DC 30V, Max. 5A/ points MPS-16A8R relay-output
COM3 P36~P39 AC 250V or DC 30V, Max. 5A/ points

Analog / Temperature inputs

channel Factory default How to change Connector / Wiring example
AI0~AI3 DC 0~5V Change input range by replacing resistors; select NTC input as an order option MPS-16A8R analog-input

PWM and High-Speed Inputs

Function Contacts / Channels Points Connector / Wiring example
I²C / Encoder / High-speed counter SDA(A), SCL(B) 1 channel MPS-16A8R counter-encoder
PWM outputs - Not supported

Communication and Upload

Function Terminals / Cables Usage Connector / Wiring example
Program download Direct USB cable connection CP210x USB to UART Bridge, MP STUDIO download / monitoring MPS-16A8R communication
I²C·RS-232·RS-485·UART 1 channel each I²C Master, Modbus RTU Slave, LS Industrial Systems Cnet(XGK) Slave
Power terminals +5V, +12V, GND DC 9~12V input

Basic I/O example

0000   [ P0:Run button ]────────────────( P32:Relay )

← Back to MPS Series comparison

en-us_products/mps_16a8r.txt · Last modified: by 127.0.0.1

Donate Powered by PHP Valid HTML5 Valid CSS Driven by DokuWiki