IsegEncodeDigit()

IsegEncodeDigit() converts one digit to segment data.

IsegEncodeDigit command operation flow

uint8_t IsegEncodeDigit(uint8_t digit)

Commands

Command Arguments Return Value Operation
IsegEncodeDigit(digit) uint8_t digit uint8_t Converts one digit to segment data.

Example

uint8_t data[4] = {
  IsegEncodeDigit(1),
  IsegEncodeDigit(2),
  IsegEncodeDigit(3),
  0x3E                    // V: F,E,D,C,B
};
 
IsegWrite(data);

Precautions

  • These commands are only for 4-digit FND displays with a TM1637 IC. They do not directly drive a generic multiplexed FND display.
  • Use display commands after successfully calling IsegBegin().
  • Initialization fails if CLK and DIO use the same pin, or if the device number is 7 or higher.
  • length + position must be 4 or less. Numbers outside the range are not displayed, and false is returned.
  • Communication may block execution for several ms. Do not call this from an interrupt service routine.
  • Do not use the specified pins simultaneously for UART, PWM, encoders, external interrupts or other functions.
  • Check the actual module and product manuals for FND power and signal voltages.