User Tools

Site Tools


en-us_commands:reference:iup

This is an old revision of the document!


Table of Contents

Iup()

Iup() returns true only at the instant the input changes from OFF to ON.

Iup command operation flow

bool Iup(uint8_t id, bool input)

Commands

Command Arguments Return Value Operation
Iup(id, input) uint8_t id
bool input
bool Returns true only at the instant the input changes from OFF to ON.

Example

const uint8_t COMMAND_INPUT = 0;
const uint8_t MOTOR_OUTPUT = 32;
 
void setup() {
  Serial.begin(115200);
}
 
void loop() {
  const bool input = IdigitalRead(COMMAND_INPUT, 5);  // Read the input repeatedly and update only if all samples match. If HIGH and LOW are mixed, retain the previous stable state.
  const bool started = Iup(0, input);  // Return true only at the instant the input changes from OFF to ON.
  const bool stopped = Idown(0, input);  // Return true only at the instant the input changes from ON to OFF.
  static bool run = false;
  Ialt(started, run);  // Toggle the specified state ON/OFF at each rising input edge.
 
  digitalWrite(MOTOR_OUTPUT, run ? HIGH : LOW);
  if (started) Serial.println(F("motor started"));
  if (stopped) Serial.println(F("command released"));
}

Precautions

Using the same id for different signals may mix their previous states. Do not set the minimum and maximum of the Iscale input range to the same value.

← Built-in Command List

en-us_commands/reference/iup.1788791735.txt.gz · Last modified: by 127.0.0.1

Donate Powered by PHP Valid HTML5 Valid CSS Driven by DokuWiki