Product Specifications

Category Quantity Terminal / Item Specifications
Programming method - - MP STUDIO
MP STUDIO2
(Ladder logic program)
Power - P24, N24 DC 12~24V (0.5A or more when using DC 24V)
Digital inputs 8 points
(Solid-state, isolated)
P0~P7 DC 0~40V; HIGH detection at DC 5V or higher
COM0 shared
NPN/PNP input support
Relay outputs 8 points
(Mechanical contacts, isolated)
P32~P39 AC 250V or DC 30V
Max. 5A/1 points, 15A/1COM
2 points/1COM
Analog inputs 4 points
(Non-isolated)
A0~A3 Set to 0(4)~20mA, DC 0(1)~5V or DC 0~10V
10bit
Temperature sensor inputs 2 points
(Non-isolated)
NTEMP channels 0·1 NTC 3950K, 10kΩ(25℃)
-40~120℃
High-Speed Counter / Encoder 2 channels
(Non-isolated)
CLK(A)·DIO(B)
SDA(A)·SCL(B)
Max. 50kHz
Channel 1 is shared with I²C
Pulse outputs 6 points
(Non-isolated)
PWM0~PWM5 DC 5V, Max. 30mA
2 timers
Communication Channels 1 channel
(Non-isolated)
I²C I²C Master
RS-485 Modbus RTU Slave
LS Industrial Systems Cnet(XGK) Slave
IBUS Master·Slave
Memory - Flash 128KB (32KB used by system)
Data Memory 8KB (1KB used by system)

Digital inputs

See the one-channel digital-input check before wiring for the first time. →

Contact COM Input type Connector / Wiring example
P0~P7 COM0 NPN/PNP inputs MPS-8A8R-S digital-input connector guide

Relay outputs

See the one-channel relay-output check before wiring for the first time. →

COM Contact Contact ratings Connector / Wiring example
COM1 P32, P33 AC 250V or DC 30V, Max. 5A/ points MPS-8A8R-S relay-output connector guide
COM2 P34, P35 AC 250V or DC 30V, Max. 5A/ points
COM3 P36, P37 AC 250V or DC 30V, Max. 5A/ points
COM4 P38, P39 AC 250V or DC 30V, Max. 5A/ points

Analog / Temperature inputs

channel Input range Setting Connector / Wiring example
A0~A3 0(4)~20mA Jumper installed MPS-8A8R-S analog-input connector guide
A0~A3 DC 0(1)~5V Jumper removed
A0~A3 DC 0~10V Change resistors and jumpers
NTEMP channels 0·1 NTC 10kΩ, 3950K Dedicated temperature sensor inputs

PWM and High-Speed Inputs

Function Contacts / Channels Points Connector / Wiring example
PWM outputs PWM0~PWM5 6 points MPS-8A8R-S pwm-output connector guide
High-speed counter / Encoder channel 0 CLK(A), DIO(B) 1 channel MPS-8A8R-S highspeed-channel-0 connector guide
High-speed counter / Encoder channel 1 SDA(A), SCL(B) 1 channel MPS-8A8R-S highspeed-channel-1 connector guide

PWM0~PWM2 share timer 1, and PWM3~PWM5 share timer 2. Set the same frequency and WIDTH within the same timer group.

Communication and Upload

Function Terminals / Cables Usage Connector / Wiring example
Program download MP Download Cable MP STUDIO download / monitoring MPS-8A8R-S communication connector guide
RS-485 485+, 485-, +5V, GND Modbus RTU Slave, LS Industrial Systems Cnet(XGK) Slave, IBUS Master·Slave
I²C communication SDA, SCL I²C Master
FND / ENCO connector CLK(A), DIO(B) Display device or high-speed input channel 0
Power terminals P24, N24 DC 12–24V input

Basic I/O example

0000   [ P0:Run button ]────────────────( P32:Relay )