analogRead2Avg()

analogRead2Avg() returns an integer average of 4~20mA input values.

analogRead2Avg command operation flow

int32_t analogRead2Avg(uint8_t ch, uint8_t samples)

Commands

Command Arguments Return Value Operation
analogRead2Avg(ch, samples) uint8_t ch — MPINO: analog pin such as A0; MPAINO: overall module channel number starting at 0
uint8_t samples — Number of moving-average read samples; up to 20
int32_t Returns an integer average of 4~20mA input values.

Example

Connect an X input module to MPAINO-8A8R(T) and select Analog Input Module → X. Set CH0 DIP switches 20mA and GND to ON, then connect the 4–20mA signal.

void setup() {
  Serial.begin(115200);
}
 
void loop() {
  const int32_t value = analogRead2Avg(0, 5);  // Read the integer moving average of up to five recent valid values.
  if (value == ANALOG_READ2_AVG_ERROR) {
    Serial.println(F("4-20mA input error"));
  } else {
    Serial.println(value);
  }
  delay(500);
}

Precautions

  • Set the MPAINO X module CH0 DIP switches 20mA and GND to ON, and wire the current input with the correct polarity.
  • An input of approximately 3.6~4.0mA returns the normal value 0; inputs below 3.6mA return an error value.
  • Error values help detect open circuits. The user must implement final alarms and safety actions in the program.
  • IanalogRead2() and IanalogRead2f() also return 65535 on error, rather than a user-range value. Check for errors before using the result.
  • The full int32_t range is available for min~max in IanalogRead2(), but if the normal range includes 65535, it cannot be distinguished from an error value.
  • analogRead2Avgf() uses state and a buffer separate from analogRead2Avg(). Using both increases SRAM usage.
  • If samples is 0 or memory allocation fails in analogRead2Avgf(), it returns the current valid corrected value as a float.
  • On MPINO, do not use analogRead2() on voltage/NTC channels that are not 4~20mA inputs.
  • For MPINO products requiring analogReference(EXTERNAL), set it first in setup().
  • IanalogWrite2() and IanalogWrite2f() are convenience outputs dedicated to 4~20mA. Avoid alternating them with IanalogWrite() on the same channel.
  • The analog output circuit requires an external 12~24V supply. USB power alone may not provide normal output.
  • Verify actual current input/output with measuring instruments after preparing a test product.