en-us_commands:reference:ianalogfilter
Table of Contents
IanalogFilter()
IanalogFilter() applies a moving average to the supplied value.
int32_t IanalogFilter(uint8_t id, int32_t raw_value, uint8_t samples)
Commands
| Command | Arguments | Return Value | Operation |
|---|---|---|---|
IanalogFilter(id, raw_value, samples) | uint8_t id — Filter IDint32_t raw_value — New input valueuint8_t samples — Number of averaging samples | int32_t | Applies a moving average to the supplied value. |
Example
void setup() { Serial.begin(115200); analogReadInit(IANALOG_SPS_128); // Set the analog input module's sampling rate. } void loop() { const int32_t raw = analogRead(A0); // Read the raw analog value of the specified channel. const int32_t filtered = IanalogFilter(0, raw, 10); // Process the supplied value using a moving average. static int32_t previous = 0; if (abs(filtered - previous) >= 5) { previous = filtered; Serial.println(filtered); } }
Precautions
- First check the supported channels and module DIP switch input ranges for the product.
- Do not use error constants as normal measurements.
- Increasing the sample count slows response and increases memory usage.
- MPINO
A0and MPAINO0do not identify the same physical input. Recheck arguments when changing product families.