TMON Box Function
Monostable / One-shot Timer
Category: Timer Box Functions
Behavior
Starts one pulse when the input turns ON and holds the done state ON for the set time. Input changes and retriggers are ignored during that pulse.
Syntax and Arguments
Syntax: TMON T0 100
- Target — timer memory T<n> (16-bit) or DT<n> (32-bit)
- Time (preset) — 10ms ticks by default (1ms or 10ms in the settings). A number (ticks), a time unit like 1m10s, or a memory address such as
D10
Behavior Example
| Run condition | Before | Command entered | Expected result |
|---|---|---|---|
| Left condition turns ON once | T0=0 | TMON T0 100 | 0 s → T0 done contact=ON; 1 s later (default unit) → OFF |
Cautions
- A numeric time is a tick count. By default, the TON family uses 10 ms per tick and the TAON family uses 100 ms per tick; you can change this for each project in Timer Unit Settings. Changing the unit also changes the actual time of a numeric value.
- If you enter a memory address such as
D10in the time field, you can change the time while running, for example from an HMI. The memory value is a tick count, not a time: with the default unit,TMON T0 D10uses 5 seconds when D10 is 500. For details, see Set the Preset from Memory.
Box Functions in the Same Category
- TON View details — On Delay Timer
- TOFF View details — Off Delay Timer
- TPL View details — Pulse Timer
- TMR View details — Retentive Timer
- TAON View details — On Delay Timer · 100ms
- TAOFF View details — Off Delay Timer · 100ms
- TAPL View details — Pulse Timer · 100ms
- TAMON View details — Monostable Timer · 100ms
- TAMR View details — Retentive Timer · 100ms
en-us_products/mpino_studio2/box_functions/timer/tmon.txt · Last modified: by 127.0.0.1